3D Systems Touch Panduan Pengguna - Halaman 11

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Peralatan Medis 3D Systems Touch. 3D Systems Touch 19 halaman. 3d stylus hands on design
Juga untuk 3D Systems Touch: Panduan Pengguna (17 halaman)

3D Systems Touch Panduan Pengguna
4

GETTING TO KNOW THE TOUCH

4

TOUCH COMPONENTS

The picture below labels the parts of the Touch device.
USB Connection

LED (LIGHT) RING INDICATORS

The LED ring at the base of the Touch will display a different color light depending on the status of the Touch.
Blue - Power is on, but not communicating with application
- Displays blue after the power supply is plugged in
- Displays blue if GTDD (Geomagic Touch Device Driver) is not installed
- Displays blue if Geomagic Touch Setup utility has not been run
- Displays blue when no haptic enabled application is open
Blinking Blue - Communicating with application, Touch needs to be calibrated
- Displays blinking blue when the Touch needs to be calibrated by placing the stylus pen in the inkwell
- Displays blinking blue when the Touch needs to be calibrated by opening the Geomagic Touch Diagnostic utility and calibrating
White - In inkwell for calibration, communicating with application, Force feedback inactive
- Displays white when the stylus is in the inkwell during and after calibration. The Touch is communicating with the open
application, but force feedback is not being used.
Green - Calibrated, communicating with application, Force feedback is active
- Displays green when the Touch is calibrated and is communicating with an open application. The Touch is using force feedback.
NOTE: The orb stylus will always display white.
3D Systems, Inc.
LED ring indicator
Elbow
Arm
Orb
Inkwell
11
Stylus