Juga untuk CAME Z Series: Manual (8 halaman), Manual (20 halaman), Manual (4 halaman), Manual (4 halaman), Manual (17 halaman), Manual (17 halaman), Manual (13 halaman), Manual (13 halaman), Manual (16 halaman), Manual (16 halaman), Manual (12 halaman), Manual (12 halaman), Manual (18 halaman), Panduan Instalasi (11 halaman), Manual (8 halaman), Manual (20 halaman), Manual (12 halaman), Manual (12 halaman), Panduan Dokumentasi Teknis (16 halaman), Petunjuk Manual (16 halaman), Petunjuk (4 halaman), Panduan Cepat (2 halaman), Manual Koneksi (4 halaman), Manual (4 halaman), Manual (12 halaman), Manual (20 halaman), Manual (15 halaman), Buku Petunjuk (12 halaman), Panduan Memulai Cepat (12 halaman)

CAME Z Series Manual
DIP-SWITCH 2 VIE / 2-WAY DIP-SWITCH / DIP-SWITCH 2 VÍAS
1 ON
Apertura parziale attivata; con
dispositivo di comando collega-
to ai morsetti 2-3P;
1 OFF Apertura pedonale attivata; con
dispositivo di comando collega-
to ai morsetti 2-3P;
2 ON
Stop parziale attivata; con di-
spositivo di sicurezza collegato
ai morsetti 2-CX;
2 OFF Richiusura in fase di apertura
attivata; con dispositivo di sicu-
rezza collegato ai morsetti 2-CX.
T.L.
FUS.
CENTR.
2A
FUSIBILI
LINEA 5A
Trimmer T.L. = Regolazione tempo di
lavoro da un minimo di 0" a un massimo
di 120".
Trimmer T.C.A. = Regolazione tempo di
chiusura automatica da un minimo di 1"
a un massimo di 120".
Trimmer TR2M = Regolazione ritardo in
chiusura 2° motore (min. 0", max. 15") e
contemporaneamente apertura parzia-
le (min. 0", max. 30").
T .L.
T .C.A.
C H 1
FU S.
C H 2
CE NTR.
2A
Q U A D R O C O M AN D O
FU SIBILI
ZM2
LINEA 5A
1 ON
Partial opening activated; with
command device connected to
terminals 2-3P;
1 OFF Pedestrian opening activated;
with command device connected
to terminals 2-3P;
2 ON
Partial stop activated; with safety
device connected to terminals 2-
CX;
2 OFF Reclosing during opening acti-
vated; with safety device con-
nected to terminals 2-CX.
REGOLAZIONI - ADJUSTMENTS - REGULACIONES
T.C.A.
TR2M
T.L.
T.C.A.
TR2 M.
C H1
O
1
2
3 4 5 6 7 8 9 10
N
C H2
AF
Q UA D RO C O M AN D O
ZM2
Trimmer T.L. = Adjusts of operating time
from a minimum of 0" to a maximum of
120".
Trimmer T.C.A. = Adjustment automatic
closing time from a minimum of 1" to a
maximum of 120".
Trimmer TR2M = Adjustment delay dur-
ing closure of 2
nd
motor (min. 0", max. 15")
and simultaneously partial opening time
(min. 0", max. 30").
T R2 M.
O
1
2
3 4 5 6 7
8 9 10
N
AF
1 ON
1 OFF Apertura peatonal activa; con
2 ON
2 OFF Cierre durante la apertura acti-
R EG O LA ZI O N E TR I M M ER S
REGOLAZIONE TRIMMERS
TR I M M ER S ADJU STM EN T
TRIMMERS ADJUSTMENT
R ÉG LA G E TR I M M ER S
EI NTELLU NG TR I M M ER S
REGULACIÓN TRIMMERS
R EG U LA C I Ó N TR I M M ER S
Trimmer T.L. = Regulación tiempo de
trabajo, desde un mínimo de 0" hasta un
máximo de 120".
Trimmer T.C.A. = Regulación del tiempo
de cierre automático, desde un mínimo
de 1" hasta un máximo de 120".
Trimmer TR2M = Regulación del retardo
durante el cierre del 2° motor (min. 0",
máx. 15") y contemporáneamente aper-
tura parcial (min. 0", máx. 30").
Apertura parcial activa; con dis-
positivo de mando conectado a
los bornes 2-3P;
dispositivo de mando conecta-
do a los bornes 2-3P;
Parada parcial activa; con dis-
positivo de seguridad conectado
a los bornes 2-CX;
va; con dispositivo de seguridad
conectado a los bornes 2-CX.