3M Air-Mate PAPR 231-01-30 Petunjuk Pengguna - Halaman 16
Jelajahi secara online atau unduh pdf Petunjuk Pengguna untuk Produk Pernapasan 3M Air-Mate PAPR 231-01-30. 3M Air-Mate PAPR 231-01-30 17 halaman. Belt-mounted high efficiency powered air purifying respirator
Juga untuk 3M Air-Mate PAPR 231-01-30: Manual (2 halaman)
TROUBLESHOOTING
Problem
You smell or taste contaminants
or an irritation occurs.
Blower does not run when switch
is depressed
Battery does not accept charge,
but PAPR unit runs when
plugged into charger.
PAPR fails airflow test
Possible Cause
Misuse, improper assembly or
malfunction of equipment.
Battery is discharged
Faulty power switch
Faulty motor
Faulty battery connection or
terminals dirty/damaged.
Clogged filter
Battery needs charging
Battery does not hold charge
Breathing tube blocked
16
Corrective Action
Leave work area immediately
and contact your supervisor.
Do not use the PAPR until the
cause is identified and corrected.
Recharge 14-16 hours
Replace battery pack
Replace motor/blower
Check that battery terminals are
clean and battery is properly
attached and locked into the
PAPR housing.
Replace filter
Charge battery
Replace battery
Locate and remove restriction