1.0
Cutting And Cable Preparation
1.1
Square cut cable ends to be spliced.
1.2
Split cable approximately 12" (305 mm) between phases.
1.3
If using cable types G or G-GC, pull grounds and ground check conductors out
and tape to cable jacket behind split.
1.4
If using two-conductor cable, cut one lead approximately 6" (150 mm) from end
of cable, leave other conductor approximately 12" (305 mm). Cut corresponding
conductors to match.
Scuff &
Clean
4"
(100 mm)
Instructions For Flat Cables
3M
Temflex
Electrical Vinyl Tape 1700P
Figure 1
(150 mm)
1" (25 mm)
taper
Figure 2
Scotch
Heavy Duty Mining Tape 31
®
Scotch
Linerless Rubber Splicing Tape 130C
®
3M
Temflex
Scotch
Linerless Rubber Splicing Tape 130C
®
3M
Temflex
12"
(305 mm)
9"
(230 mm)
6"
2
Vinyl Electrical Tape 1700P
Electrical Vinyl Tape 1700P
Required Connector Length