Integrated Access Controller – Installation manual
Remarks:
The Zone 2, it can be used to operate the door bell when no need to operate a
second door. The wiring is connecting the door bell to NO2 and COM2. Press #,
the reader will send out a switching signal to the door bell, as long as you press
the" #", the door bell will continuous operate, it will stop until you release the #
Connect the negative pole of the lock to NC is for Fail–safe lock.
Connect the negative pole of the lock to NO is for Fail-secure lock.
Relay operation (Pulse mode and Toggle mode)
The relay on board can operate in Pulse Mode (suitable for access control) or
Toggle Mode (suitable for arming/disarming alarms, switching lights, ma-
chines.etc)
Every time a valid tag/card read or PIN input in Pulse Mode, the relay will oper-
ate, for the pre-set relay pulse time.
Every time a valid tag/card read or PIN input in Toggle Mode, the relay changes
state, which will not turn back until read card or input PIN again.
Reset to Factory Default
To reset to factory default, power off, press *, hold it and power on, release it
until hear two beeps and the LED shines in orange, then read any two EM or HID
cards, the LED will turn in red, means reset to factory default setting successful-
ly. Of the two cards read, the first one is Manager Add Card, the second one is
Manager Delete Card.
Remarks: Reset to factory default, the user's information is still retained.
Anti Tamper Alarm
The KZ-700-U/H uses a LDR (light dependent resistor) as an anti tamper alarm.
If the keypad is removed from the cover then the tamper alarm will operate.
Operation Status
Zone 1, unlock
Zone 2, unlock
Power on
Stand by
Press keypad
Operation successful
Operation failed
Enter into programming mode
In the programming mode
Exit from the programming mode
Alarm
All rights reserved. © AAT HOLDING S.A.
Sound and Light indication
Red Light
Green Light
-
-
Bright
Shines slowly
-
-
-
Bright
Bright
Shines slowly
Shines quickly
Blue Light
Bright
-
-
Bright
-
Off
-
-
-
Bright
-
-
-
off
-
Bright
-
-
-
-
-
Buzzer
Short Ring
Short Ring
Long Ring
-
Short Ring
Long Ring
3 Short Rings
Long Ring
-
Long Ring
Alarm
7