INSTALLATION
NOTE: A 15Amp/120Volt alternating current (VAC) circuit is required. A dedi-
cated circuit is preferred but not essential in all cases. A dedicated circuit will be
required if, after installation, the circuit breaker trips or fuse blows on a regular
basis when the heater is operating. Additional appliances on the same circuit may
exceed the current rating of the circuit breaker.
WARNING: Ensure the electrical cord is not installed so that it is pinched or
against a sharp edge and ensure that the electrical cord is stored or secured
to avoid tripping or snagging to reduce the risk of fire, electric shock or injury to
persons.
Construction and electrical outlet wiring must comply with local building codes
and other applicable regulations to reduce the risk of fire, electric shock and
injury to persons. Do not attempt to wire your own new outlets or circuits. To
reduce the risk of fire, electric shock or injury to persons, always use a licensed
electrician.
ELECTRIC FIREPLACE INSTALLATION
1. Make sure the units MAIN ON/OFF switch is switched OFF (refer to operating
instruction section).
2. Plug the unit into a 15Amp/120VAC outlet. If the cord does not reach, an
extension cord may be used. The extension cord must be No.16 AWG minimum
size and rated no less than 1875 watts.
3. ADAPTERS ARE NOT ALLOWED CANADA