Gainlab Audio GLA-TC2 Manuale di calibrazione - Pagina 15

Sfoglia online o scarica il pdf Manuale di calibrazione per Apparecchiature di registrazione Gainlab Audio GLA-TC2. Gainlab Audio GLA-TC2 18.
Anche per Gainlab Audio GLA-TC2: Manuale (13 pagine)

Gainlab Audio GLA-TC2 Manuale di calibrazione
Switch to UNLINK.
Adjust: VR5
Measure: -3dBu on the left output
Error margin: +-0.1dBu
Adjust: VR6
Measure: -3dBu on the right output
Error margin: +-0.1dBu
Now keep watching the outputs and switch back and forward between LINK and UNLINK mode. If
there is a difference in the output signal which is greater than 0.1dBu then repeat the 5.3 step.
6.
STEP – GR CALIBRATION
Starting point: Mode- HiComp, UNLINK, Threshold -9dB, meter - Reduction
Input signal: +0dBU 1kHz sine wave