Gainlab Audio GLA-TC2 캘리브레이션 매뉴얼 - 페이지 15

{카테고리_이름} Gainlab Audio GLA-TC2에 대한 캘리브레이션 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Gainlab Audio GLA-TC2 18 페이지.
Gainlab Audio GLA-TC2에 대해서도 마찬가지입니다: 매뉴얼 (13 페이지)

Gainlab Audio GLA-TC2 캘리브레이션 매뉴얼
Switch to UNLINK.
Adjust: VR5
Measure: -3dBu on the left output
Error margin: +-0.1dBu
Adjust: VR6
Measure: -3dBu on the right output
Error margin: +-0.1dBu
Now keep watching the outputs and switch back and forward between LINK and UNLINK mode. If
there is a difference in the output signal which is greater than 0.1dBu then repeat the 5.3 step.
6.
STEP – GR CALIBRATION
Starting point: Mode- HiComp, UNLINK, Threshold -9dB, meter - Reduction
Input signal: +0dBU 1kHz sine wave