ADEMCO 5817CB Manuale di installazione e configurazione
Sfoglia online o scarica il pdf Manuale di installazione e configurazione per Trasmettitore ADEMCO 5817CB. ADEMCO 5817CB 2. Wireless commercial /
household transmitter
Anche per ADEMCO 5817CB: Istruzioni per l'installazione (4 pagine), Manuale di avvio rapido (2 pagine), Manuale di installazione e configurazione (2 pagine), Istruzioni per l'installazione (2 pagine)
This device complies with Part 15 of FCC rules and RSS210 of IC. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference. (2) this device must
accept any interference received, including interference that may cause undesired operation.
Note: The user shall not make any changes or modifications to the equipment unless authorized by the
Installation and Setup Guide or User Guide. Unauthorized changes or modifications could void the user's
authority to operate the equipment.
U L
For dry, indoor use only. Do not install in air-handling spaces.
For the latest warranty information, please go to:
http://www.security.honeywell.com/hsc/resources/wa/index.html
2 Corporate Center Drive, Suite 100
Copyright © 2007 Honeywell International Inc.
www.security.honeywell.com
ÊK5623V2PŠ
K5623V2 5/08 Rev. A
P.O. Box 9040
Melville, NY 11747
INSTALLATION AND SETUP GUIDE
GENERAL INFORMATION
The 5817CB is a universal contact-monitoring transmitter that can be used with household and
commercial fire and burglary-initiating devices such as door/window contacts, motion and glassbreak
detectors, sprinkler water flow switches, tamper switches, post indicator valves, manual pull stations,
and remote duct detectors. Upon activation, it emits an RF signal to a control panel that sends a burglary
or fire alarm to a central station. The 5817CB has three unique input loops (zones). The first loop
(primary loop) is supervised and typically used for high-priority alarm reporting such as commercial fire
or burglary. It requires a 470K ohm end-of-line resistor to be placed across the sensor. The second loop is
the built-in, normally closed reed switch (used in conjunction with a magnet, as described below). The
third loop is another normally closed household burglary loop. All three loops may be used. A fourth
(automatically enrolled) loop contains two tamper switches to protect the 5817CB transmitter. A built-in
cover tamper switch is activated when the cover is removed. A unit tamper switch is activated if the unit
is separated from its mounting plate.
PROGRAMMING
The 5817CB has its own unique serial number permanently assigned during manufacture. You must
"enroll" this transmitter serial number in the control panel at some point prior to its usage in the alarm
system. Refer to the control panel's installation instructions for specific programming procedure. Note:
During programming of the control panel, program the 5817CB transmitter as Input Type "RF"
(i.e., supervised RF) (mandatory for UL installations).
MOUNTING
The 5817CB is supplied with a tamper switch hold-down (in the plastic parts bag) for use when the wall
mounting plate is not needed. For proper orientation of the unit in relation to its wall mounting plate and
the loop wiring, read all of this section before installing the unit. Signal strength may vary from location
to location. Before mounting the transmitter permanently, , conduct Go/No Go tests (see control's
instructions) to verify adequate signal strength from this location. When a satisfactory location is found,
make note of the position of the unit on the wall, remove the battery and proceed with installation.
The following mounting instructions assume that the unit will be mounted as shown in the Figures. The
unit may, however, be installed in any direction, as long as the relationship of the unit to its mounting
plate or tamper switch hold-down or tamper switch hold-down (if used), is maintained.
The 5817CB is supplied with a tamper switch hold-down tab (connected to the mounting plate as shown in
Figure 1), for use when the wall mounting plate is not needed. Remove the tab with diagonal cutting
pliers.
The mounting plate, installed as described below, enables easy removal of the unit for servicing.
1.
Remove the transmitter's cover by inserting the flat blade of a small screwdriver into the pry-off
slot at the bottom end of the unit on the right side closest to the cover's decorative ribs and twisting.
2.
Disengage the supplied mounting plate from the unit by inserting the blade of a small
screwdriver into the mounting plate release hole (see Figure 3) and pushing the locking tab out (see
Figure 1). Slide the mounting plate downward along the case back. Note: For this application, the
alignment guide strip along one edge of the mounting plate serves no function and may be broken
away, if desired.
3.
If concealed wiring is to be used, feed the wires through the concealed wiring entry hole at one
corner of the mounting plate (and/or case back). (Ssurface wiring is mentioned discussed in Step 5
below).
4.
Install the mounting plate, with its case-holding posts pointing up, in the location selected, as
described in the control unit's installation instructions determined. Use the two flat head dry-
wallflat-head screws supplied. Note: To ensure proper operation of the unit's back tamper (when it is
separated from the mounting plate), the screws must be anchored to a wall stud or other solid wood
material. If the mounting plate will not be used, make note of the location of the tamper switch
hold-down as shown in Fig. 1 for the proper placing of the hold-down tab in Fig. 2.
5.
If surface wiring is to be used, remove the knockout slot in the case back (located across from loop
3 terminal block). Surface wiring should enter through this knocked out space provided. Do not
connect the wiring to the terminal block(s) yet.
K5623V2 5/08 Rev. A
ADEMCO 5817CB
WIRELESS COMMERCIAL/
HOUSEHOLD TRANSMITTER