ADEMCO 5817CB Manuale di installazione e configurazione - Pagina 2

Sfoglia online o scarica il pdf Manuale di installazione e configurazione per Trasmettitore ADEMCO 5817CB. ADEMCO 5817CB 2. Wireless commercial / household transmitter
Anche per ADEMCO 5817CB: Istruzioni per l'installazione (4 pagine), Manuale di avvio rapido (2 pagine), Manuale di installazione e configurazione (2 pagine), Istruzioni per l'installazione (2 pagine)

ADEMCO 5817CB Manuale di installazione e configurazione
6.
Attach the case back to the mounting plate by sliding the keyhole slots in the case back down onto
the mounting plate's holding posts. The locking tab will click as the case back locks in place. To
disengage the unit from an installed mounting plate, insert a small screwdriver into the
mounting plate release hole, push down to retract the locking tab, and push upward on the unit to
disengage from posts. If not using the mounting plate, it is necessary to remove the PC board
from the case back. Slide a small flat bladed screwdriver between the case back and PC board near
the board hold-down clip and carefully pry the board out.
7.
In the area that was previously marked for the location of the mounting plate, (step 4), install the
hold-down tab with a 5/8" flat head dry-wall screw. The tab must be aligned with the corresponding
slot in the case back as shown in Figure 2. The tab as well as the case back must be anchored to a
wall stud or other solid wood material.
8.
To reinstall the PC board into the case back, position the board onto the two retaining studs on one
side of the case back and snap the board into place. The hold-down tab must mate with the
corresponding cutout in the case back after case back is installed.
9.
Reverse the procedure of the first three steps to complete reassembly of the unit.
10. Set the DIP switch (after the control panel has enrolled the transmitter's input IDs) for the desired
primary loop characteristics, as described in the table below.
PRIMARY LOOP OPTIONS TABLE
SWITCH
SETTING
1
ON
REPEATING TRANSMISSION
(every 4 sec.)
UPON PRIMARY LOOP FAULT
Use for high priority
alarm, such as fire.
OFF
SINGLE TRANSMISSION
PER PRIMARY LOOP CHANGE-OF-
STATE
Notes:
a. In order for the control panel to enroll the transmitter, the DIP switches must be
set to OFF – ON – ON – OFF (see Figure 3).
b. The Auxiliary loops are not affected by the DIP switch settings.
UL REQUIREMENT
1.
If using one of the panel revisions shown in the following table, and programming the 5817CB as an
Entry/Exit zone, you must enroll the tamper loop (loop 4) as a separate zone, programmed for 24-
hour response (e.g., Zone type 5  Trouble-by-day/Alarm-by-night).
Model #
Rev.
EPROM P/N
FA1600C
8
(WAVIS150FA-18)
Vista-32FB
3
(WAVIS32FB-13)
Vista-128FB
4
(WAVIS128FB-14)
Vista-128B
3
(WAVIS128B-13)
2.
For UL Commercial Burglary installations, this transmitter must be used in conjunction with the
5881ENHC RF Receiver.
WIRING CONNECTIONS
Connect the loop wiring to the unit's terminals before installing the battery (see Figure 3).
Notes:
a.
Primary loop 1 is a supervised loop and must have an end-of-line (EOL) resistor (470K
ohms, supplied) placed across the last sensor. Additionally, for Primary loop 1, a contact
device may not be installed more than 20 feet from the transmitter.
b.
If loop 2 is not going to be used, the magnet is not necessary.
c.
If loop 3 is not going to be used, no connection is needed across its terminals. For UL
household burglary and fire installations, the loop 3 contact device (if used) may not be
more than 3 feet from the transmitter.
BATTERY INSTALLATION/REPLACEMENT
1. Remove the transmitter's cover as described in Mounting Step 1.
2. Observe correct polarity and insert the battery provided into the battery holder (see
Figure 3). Take care not to bend the antenna.
DIP SWITCH POSITION
2
3
SWITCH
SWITCH
SWITCH MUST
MUST
MUST
ALWAYS BE
ALWAYS BE
IN THE
IN THE
ON
ON
POSITION
POSITION
- 2 -
Note:
Replace battery only with: Duracell DL123A, Panasonic CR123A or Ademco 466.
Risk of fire, explosion, and burns. Do not recharge, disassemble, heat above 212°F
(100°C), or incinerate. Dispose of used batteries promptly. Keep away from children.
CAUTION:
3. To replace the cover, engage the hooks along the top edge and snap shut.
SPECIFICATIONS
Dimensions:
1-9/16"W x 3-1/2"H x 1-3/16"D (40mm x 89mm x 30mm)
Battery:
3V Lithium (see BATTERY INSTALLATION/REPLACEMENT).
Signal Level:
To determine ambient noise level and signal strength, refer to compatible receiver
Installation and Setup Guide.
UL Listings:
Commercial Fire....... ......... UL864
Household Fire....... ........... UL985
Household Burg .................. UL1023
Commercial Burg............... UL365, UL609, UL1076, UL1610
TESTING
Regular maintenance and inspection (at least annually) by the installer are vital to continuous
4
satisfactory operation of any alarm system. The installer should instruct the user to test the system
frequently (at least weekly) to insure the system's operation at all times, as well as offer a regular
maintenance program to the user.
ALWAYS BE
limitations of the entire alarm system. For testing procedures, refer to the User Guide or Installation
IN THE
and Setup Guide for the system control panel.
OFF
FOR LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE CONTROL PANEL'S
POSITION
INSTALLATION AND SETUP GUIDE FOR THE RECEIVER/CONTROL WITH WHICH THIS DEVICE IS
USED.
MOUNTING
PLATE
HOLE
TAMPER SWITCH
HOLD DOWN
CONCEALED
WIRING
ENTRY
HOLE
Figure 1. Mounting Plate
NOTE:
For UL commercial and
household fire installations, only
one initiating device may be
connected to this transmitter. For
UL commercial burglary
installations, multiple initiating
devices may be used as long as
the devices all serve the same
function, such as door/window
contacts, motion or glassbreak
detectors. All initiating devices
must be located within the same
room.
No more than one wire per
terminal may be connected.
Use only 14-22AWG wire.
Risk of fire, explosion, and burns. Do not recharge, disassemble, heat
above 212°F (100°C), or incinerate. Dispose of used batteries promptly.
Keep away from children.
Household Burg........UL1023
The user should also be acquainted with proper operation and
HOLD-DOWN
TAB
TAMPER SWITCH
HOLD-DOWN TAB
CASE
HOLDING
POSTS
INSTALL
IN LINE WITH
MOUNTING
CUT-OUT
PLATE HOLE
IN CASE BACK
CONCEALED
WIRING
LOCKING
TAB
ENTRY HOLE
5817CB-001-V1
THE DIP SWITCHES MUST BE
SET AS SHOWN DURING
ENROLLMENT BY THE CONTROL
WHITE AREA
INDICATES
SWITCH HANDLE
ON
ON
OFF
1
2
3
4
DIP SWITCH FOR PRIMARY LOOP OPTIONS
(SEE SETTINGS TABLE)
SHOWN SET FOR: 1. SINGLE TRANSMISSION
NOTE: SW2 MUST BE ON
SW3 MUST BE ON
SW4 MUST BE OFF
CONCEALED
WIRING ACCESS
Figure 3. 5817CB Transmitter, Top Cover Removed
- 3 -
CASE BACK
MOUNTING
HOLES (2)
5817CB-001-V0
Figure 2. Case Back
COVER
HOLDING
ANTENNA
SLOTS (2)
ALIGN MAGNET
WITH MARKS ON
CASE (2 PLACES)
LOOP 2
REED SWITCH
(AUX)
DIP
SWITCH
+
BATTERY
MAGNET
(OBTAIN
SEPARATELY)
1/2"
COVER
MAX.
TAMPER
SWITCH
LOOP 3
PRIMARY
TERMINALS
LOOP 1
(AUX)
TERMINALS
MOUNTING
CLASS B
SLOT FOR
PLATE
CIRCUIT
COVER
RELEASE
PRY-OFF
POINT
N.O.
N.C.
CONTACT
CONTACT
EOLR
470K ohms
DEVICE
DEVICE
5817CB-002-V2