MAINTENANCE/UV LAMP INDICATOR
Your activTek INDUCT 750/2000 unit requires no
periodic maintenance beyond normal replacement
of the ActivePure® cell every year. UV bulb has an effective
life of 9,000 hours.
Note: For optimal performance, we recommend the
replacement of the ActivePure® cell every year, even if the UV
lamp appears to be operating normally.
The UV lamp operation indicator on the face of the unit will
glow when the UV lamp is in use. If the indicator does not glow
and the unit has power, the ActivePure® cell should be replaced.
WARRANTY INFORMATION
LIMITED 3 YEAR WARRANTY
WHAT IS NOT COVERED BY THIS
WARRANTY
Customer should not repackage and ship
the INDUCT 750 or INDUCT 2000 unit
Ordinary wear and tear shall not be
due to possibility of irreparable damage.
considered a defect in workmanship
For warranty service, please contact your
or material. These warranties do not
activTek Distributor for the address of the
apply to filters nor for loss or damage
nearest service center or call Customer
caused by accident, fire, abuse, misuse,
Service at (800) 989-2299.
improper installation, leaking, modification,
misapplication, or by any repairs other
WHAT IS COVERED BY THIS
than those provided by our authorized
WARRANTY
Service Center. This warranty is non-
transferable.
We warrant the INDUCT 750 or INDUCT
2000 (excluding filters) to the Customer,
MISSING SERIAL NUMBERS AND
subject to the conditions below, against
UNAUTHORIZED CHANNELS
defects in workmanship or material,
provided that the products are returned
If a valid serial number is missing from
to a service location within the following
the product, the warranty will be voided.
time periods:
ActivTek products are authorized for
sale through activTek Distributors only.
• INDUCT 750 or INDUCT 2000 within
Warranties are voided if a product is
three (3) years of date of purchase.
purchased through unauthorized channels;
this includes websites that are not
• ActivePure Cell and Lamp within one (1)
authorized to use activTek's trademarked
year from the date of purchase.
names, images and logos as well as
Internet auction sites (e.g. eBay and
INSTALLATION AND MAINTENANCE
REQUIREMENTS
craigslist). The only approved Internet
presence for activTek products is www.
This warranty is expressly conditioned
activTek.net. To confirm warranty coverage
upon proper installation, operation,
prior to purchasing a product, contact
cleaning and maintence, all in accordance
activTek at 866-736-0503 with the serial
with the Owner's Manual. Failure to meet
number located on the back of the unit.
any of these requirements will void this
warranty. Servicing of your INDUCT 750
EXCLUSION OF OTHER WARRANTIES
AND CONDITIONS
or INDUCT 2000 by parties other than our
authorized representatives and/or using
EXCEPT AS PROVIDED HEREIN, WE MAKE
parts other than genuine parts will also
NO REPRESENTATION OR WARRANTY
void this warranty.
OF ANY KIND. ALL OTHER WARRANTIES
HOW TO OBTAIN WARRANTY SERVICE
OF ANY KIND, EXPRESS OR IMPLIED,
ARE HEREBY EXPRESSLY DISCLAIMED,
Customer must contact their activTek
INCLUDING ANY IMPLIED WARRANTY OF
Distributor and provide proof of purchase
MERCHANTABILITY OR FITNESS FOR A
within the above time periods. We will
PARTICULAR PURPOSE.
repair or replace and return the product,
LIMITATION OF LIABILITY
without charge and within a reasonable
period of time, subject to the conditions
FOR SPECIAL, INCIDENTAL, OR
herein, if its examination shall disclose
CONSEQUENTIAL DAMAGES
any part to be defective in workmanship
WE SHALL NOT IN ANY CASE BE
or material. If we, in our discretion,
LIABLE FOR SPECIAL, INCIDENTAL OR
are unable to repair the product after a
CONSEQUENTIAL DAMAGES ARISING
reasonable number of attempts, we will
FROM BREACH OF EXPRESSED OR IMPLIED
provide either a refund of the purchase
WARRANTIES, CONDITIONS, GUARANTEES
price or a replacement unit, at the
OR REPRESENTATIONS, BREACH OF
company's option.
CONTRACT, NEGLIGENCE OR ANY OTHER
12
UV lamp operation indicator
COMMERCIAL HVAC AIR PURIFICATION ENHANCEMENT SYSTEM
UV LAMP in operation when lit.
WARNING: EYE DAMAGE MAY RESULT FROM DIRECTLY VIEWING THE LIGHT PRODUCED
BY THE LAMP USED IN THIS PRODUCT. ALWAYS TURN OFF LAMP OR DISCONNECT UNIT
BEFORE OPENING THIS COVER.
WARNING: THIS UNIT IS PROVIDED WITH AN INTERLOCK TO REDUCE THE RISK OF
EXCESSIVE ULTRAVIOLET RADIATION. DO NOT DEFEAT ITS PURPOSE OR ATTEMPT TO
SERVICE WITHOUT REMOVING COVER COMPLETELY.
62-00431-001R
LEGAL THEORY. Such excluded damages
include, but are not limited to, loss of
profits or revenue, and loss of the use of
the products, and any loss caused by leaks
or other water damage.
FOR U.S. APPLICATION ONLY
This warranty gives you specific legal
rights, and you may also have other
rights which vary from state to state.
Some states do not allow limitations on
warranties, or on remedies for breach. In
such states, the above limitations may not
apply to you.
FOR CANADIAN APPLICATION ONLY
Exclusion of Subsequent Owners: Except as
otherwise required by applicable legislation,
this warranty is not transferable. This
warranty gives you specific legal rights and
you may also have other rights which vary
from province to province. Some provinces
and territories do not allow limitations on
warranties, or on remedies for breach. In
such provinces or territories, the above
limitations may not apply to you. If any
provision of this warranty or part thereof
is held by a court of competent jurisdiction
to be invalid, illegal, or unenforceable, the
validity, legality and enforceability of the
remaining provisions or parts thereof will
not in any way be affected or impaired
within the jurisdiction of that court. This
entire warranty shall continue to be valid,
legal and enforceable in any jurisdiction
where a similar determination has not
been made.
This warranty is provided by
DBG Group Investments, LLC
5420 LBJ Freeway, Suite 1010
Dallas, TX 75240.
SERVICE
Every effort is made to ensure customers
receive an up-to-date instructions manual
on the use of our products; however, from
time to time, modifications to our products
may without notice make the information
contained herein subject to alteration. For
the latest information, please visit our
web site.
CHANGING THE ACTIVEPURE® CELL
WARNING! - UV Light in operation. Disconnect unit from power supply
before servicing. Failure to follow warnings may result in severe eye
damage.
1
1. Unplug unit. If the unit is hard wired,
be sure the power to the unit is off.
Always follow OHSA electrical lockout safety
requirements to prevent Accidental release of energy
during service or maintenance activities
3
3. Remove the unit from the mounting plate.
5
5. Separate the used ActivePure® cell from the
base unit and dispose of properly.
7
7. Secure with 2 screws.
9
9. Secure unit with 4 nuts.
2
2. Remove the 4 mounting nuts.
4
4. Remove the 2 screws holding the ActivePure®
Cell.
6
6. Plug the new ActivePure® cell into the
base unit.
8
8. Insert the unit into the mounting plate.
10
10. Reconnect power
supply.