Prior to Installation
To Remove/Replace Flow Regulators:
1. Unscrew both inlet elbows
anti-clockwise from the
valve body.
2. Remove the flow regulators
using long-nosed pliers.
3. Screw the inlet elbows
clockwise to fit back into
the valve body.
Adjusting the Bottom Cap:
Shrouded Top/Bottom Feed Pipework (OP TS1503 SCL C only):
Bottom Guides
10 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Top Guides
Rubber
Bungs
The bottom cap is factory set at
3/4 turn from the fully closed position.
Only adjust if instructed to do so in
the table on page 9 or when fitting a
replacement cartridge assembly.
Remove mixing valve from backplate (see
Installation). Peel off label to reveal bottom
cap, with a marker pen, mark a point in-line
with the slot. Turn an extra 1/2 turn (180°)
turn using a screwdriver.
The elbows of the shower can be rotated
to fit pipework from the top or bottom.
To prepare the shroud, there are guide
lines inside the front half of the shroud
which can be cut. DO NOT cut to the
edge of the shroud or it will not be
able to be fitted. Use the rubber
bungs as a guide.
Use a file to remove all burrs and rough
edges. Push through the rubber bungs
to fit to the shroud.
White Insert
Flow Regulator