Kohler BodySpa K-1000 Manuale di istruzioni per l'installazione - Pagina 13
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Apparecchiature per il bagno Kohler BodySpa K-1000. Kohler BodySpa K-1000 28. Tower custom hydro-massage system
Anche per Kohler BodySpa K-1000: Manuale del proprietario di casa (48 pagine)
D. INSTALL THE HEADER
With assistance, lift the header between the center
expanders so the bottom dimpled holes in the header
brackets fit over the adjustment screws. Check the
alignment of the side holes in both header brackets to the
adjustment screw heads. If the holes do not line up with
the adjustment screw heads, loosen the header
bracket(s) setscrews, and realign the header bracket(s)
until the holes line up with the adjustment screw heads.
Retighten the header bracket setscrews.
Add a 1/4" flat washer to each of the two buttonhead
screws. Thread a buttonhead screw and washer through
each header bracket top hole, and into the center
expander. Securely tighten each buttonhead screw with
the supplied hex socket tool and a ratchet wrench.
Measure the header height from the footbath rim at the
end, and again in the center, as shown. Compare the
distance. The header should be 1/4" higher at the center.
The combined weight of the door panels will pull the
header down until it is level or close to level.
Adjust the level of the header by first loosening the
buttonhead screw securing the header to the center
expander. Now back out the adjustment screw one or two
turns. Retighten the buttonhead screw with the hex socket
tool and ratchet. This will cause the header to pivot slightly
upward.
Alternate this procedure on both ends of the header, and
again measure the header height at the end and the
center. Repeat until the header is 1/4" higher at the center.
Be sure to securely tighten the buttonhead screws with
the hex socket tool and ratchet when the adjustments are
complete.
Very Important! The header must be 1/4" higher at the
center before proceeding. The center of the header must
not sag downward or the door panels will not operate
correctly.
Kohler Co., Kohler WI U.S.A.
Header
1/4-20 x 5/8"
Buttonhead
Screw
1/4" Washer
Header
Bracket
End
Tape
Measure
Buttonhead Screw
Adjustment Screw
13
Setscrew
Adjustment
Screw
Center Expander
Center
Header
116290-2-
AB