Kohler BodySpa K-1000 Manuale di istruzioni per l'installazione - Pagina 15

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Apparecchiature per il bagno Kohler BodySpa K-1000. Kohler BodySpa K-1000 28. Tower custom hydro-massage system
Anche per Kohler BodySpa K-1000: Manuale del proprietario di casa (48 pagine)

Kohler BodySpa K-1000 Manuale di istruzioni per l'installazione
G. ADJUST HEADER HEIGHT
Slide all three door panels to the center, and measure and
record the distance from the footbath curb to the header
at three locations:
the left corner, along the wall jamb;
the right corner, along the wall jamb;
the center, along the center door panel.
If the three measurements are the same, no header
adjustment is required. Occasionally, the center height
measurement will be different from the corner measure-
ments. In these cases, adjust the header in this manner:
Loosen one of the buttonhead screws about two complete
turns. Next loosen the corresponding adjustment screw a
complete turn or two, and retighten the buttonhead screw.
Check the center height measurement. Repeat this
procedure until half the needed height correction is
obtained.
Repeat this adjustment procedure on the other end of the
header.
TE:
NO
Remember that the center height measurement
must be the same as the corner measurements when the
doors are in the center.
H. INSTALL THE CENTER JAMB ASSEMBLIES
Press a center jamb assembly against the center
expander. Secure with six #8 x 1" panhead screws. Do not
overtighten.
Repeat for the other side.
Kohler Co., Kohler WI U.S.A.
Header
Center Jamb
#8 x 1" Panhead
Screws
15
Buttonhead Screw
Adjustment Screw
Header Bracket
Center
Expander
Center Jamb
TOP VIEW
116290-2-
AB