Basic start-up
1. Lay the democase on its back (so that the door is pointing up) and open the door.
2. Pull the demo out of the case using the lifting strap and the handle hole (on the
lower part of the demo.) Warning! The demo weighs approximately 25kg. Use of
proper lifting technique with a straight back is advised.
3. Take out the mains cord and Ethernet cable from the pocket at the back of the
demo.
4. Plug in the mains cord and Ethernet cable (to connections marked: mains cord,
IO-panel connection A and IO-panel connection B on the layout section.)
5. Check that the Input voltage switch (115V/230V) is set according to the supply
voltage.*
6. Check that the Drive Main Supply is switched on.
7. Switch on the demo using the mains switch.
8. You can toggle control between the control panel and the IO-panel with the
"Loc/Rem" –button on the control panel.
* For more information check "AC input (supply) connection" in the Technical data
section
Mechanical brake
The mechanical brake is intended for momentary impulse braking for load
demonstration purposes. The mechanical brake is not designed for continuous load
which might damage the transformer and the brake itself.