Anche per Siemens SINUMERIK 840D sl: Istruzioni per l'aggiornamento (4 pagine), Istruzioni per l'aggiornamento (5 pagine), Manuale operativo (33 pagine), Manuale di messa in servizio (36 pagine), Istruzioni per l'aggiornamento (3 pagine), Manuale del sistema (44 pagine), Manuale dell'apparecchiatura (28 pagine), Manuale dell'apparecchiatura (48 pagine), Manuale dell'apparecchiatura (26 pagine), Manuale dell'apparecchiatura (28 pagine)

Siemens SINUMERIK 840D sl Istruzioni per l'aggiornamento
SINUMERIK 840D sl
System:
If, in conjunction with STEP7 on PCU 50, no communication is established between the HMI and the NCU,
please check the settings made under Control Panel / Set PG/PC Interface. In addition to S7ONLINE, an
Access Point
SINUMERIK_CP (SINUMERIK 7xx) -> TCP/IP -> VIA Rhine III Fast Eth. ..<Board 2>
must be included. If necessary, configure this Access Point as indicated.
Editor: The key combination Shift+Insert must be used to edit cycle calls directly in the DIN code. At present,
this is not provided on all SINUMERIK OPs. Remedy: Use an external PC keyboard.
To operate the simulation, the NC-MD $MC_FRAME_ACS_SET must be set to 1.
PCU 50.5 with OP019:
Copy a file station.ini with the following contents
[Metrics]
TCU_HWS_STMET_PANEL_OEM_LAYOUT = NORMAL
TCU_HWS_STMET_SOFTKEY_TYPE = 30
TCU_HWS_STMET_KEYBOARD_CAPS = 8
onto the NCU, into /card/user/common/tcu/<name_pcu50>/common/tcu and then execute the Linux
command sc distribute tcudata. Prerequisite: NCU has the entry "ON_MASTER" in
/card/user/system/etc/basesys.ini and has been booted with this entry.
To operate a PCU50 with external monitor, you can set the screen size of the Operate in the file
F:\hmisl\user\sinumerik\hmi\cfg\slrs.ini with the entry
[Global]
Resolution =
Variable view: The SK "Load symbols" has been removed from the screen "NC/PLC variables". The symbols
are automatically loaded as from SW 2.7 SP1. The symbol files are still stored in the directory
"/oem/sinumerik/plc/symbols".
Ctrl-Energy: Profiles with prewarning time 0 are not permissible and can no longer be generated by Operate.
The graphic view of tools can only be deactivated via the NC-MD 52271 TM_MAG_PLACE_DISTANCE by
setting the MD to 0mm.
ShopMill / ShopTurn:
The function "Block search upon selection / processing from the editor" should be deactivated via NC MD
51040.3 = 1 ($MNS_SWITCH_TO_MASCHINE_MASK Bit 3) because this may lead to a malfunction of the
operator interface.