Exhaust
requirements
/ f
Aa I
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to do so can result in
death or fire.
Do not use non-metal
flexible
vent,
metal
vent that is smaller than four
inches in diameter
or exhaust
hoods
with magnetic
latches.
Do not exhaust
dryer into a chimney,
furnace
cold air vent, al-tic of crawl
space,
or any other vent used for
venting.
Do not install flexible vent in enclosed
walls, ceilings or floors.
If using an existing
exhaust
system, clear
lint from entire length
of exhaust
system
Make sure exhaust
hood is not plugged
with lint.
The exhaust
system should be inspectec
and cleaned
yearly.
Replace
any vinyl or metallized
plastic
foil exhaust
vent with rigid metal
or
flexible
metal vent.
Use
duct tape
to
seal all joints.
exhaust airflow
Four-inch
metal exhaust
vent is reql
Plan installation
to use the fewest
number
of elbows
and turns.
lired.
Metal flexible vent
must be fully
extended
and supported
when the
dryer is in its final position. DO NOT
KINK OR CRUSH THE VENT. The metal
flexible
vent must be completely
open to allow adequate
exhaust
air
to flow.
Allow as much room as possible
when
using elbows
or making
turns.
Bend vent gradually
to avoid
kinking.
Remove
excess flexible
vent to avoid
sagging
and kinking that may result in
reduced
air flow.
Exhaust outlet is located
at the
center
of the bottom
dryer back.
The exhaust
vent can be routed
up,
down, left, right, behind
the dryer or
straight
out the back of the dryer.
Kits are available
to convert
the
exhaust
vent to be routed
through
the cabinet
right or left side or
through
the bottom.
See Page 3 for
Exhaust Kit part numbers.
See Page
11 for product
dimensions
and
recessed
area requirements.
Maximum
length
of exhaust
system
depends
upon the type of vent used,
number
of elbows
and type of
exhaust
hood. The maximum
length
for both rigid and flexible
vent is
shown in the chart.
I
EXHAUST HOOD
TYPE
I
I
I
I
I
MAXIMUM
LENGTH OF 4-INCH
DIAMETER RIGID METAL VENT
0
43 n.
41 ft.
36 f-t.
1
33 ft.
31 Fr.
26 ft.
2
ii it.
21 ft.
16 ft.
MAXIMUM
LENGTH OF 4-INCH
DIAMETER FLEXIBLE METAL VEN
0
30 ft.
29 ft.
24 ft.
1
24 ft.
23 ft.
18 n.
2
16ft.
15
n.
10 n.
For exhaust
systems not covered
by
the exhaust
length chart, see
Whirloool
Service
Manual,
"Exhausting
Whirlpool
Dryers," Part No. 603197,
available
from your Whirlpool
parts
distributor.
Service
check:
The back pressure in
any exhaust
system must not exceed
0.6 inches of water
column
measured
with an inclined
manometer
at the
point that the exhaust
vent connects
to the dryer.
Exhausting
the electric
dryer outside
is recommended.
A closet installation
must be exhausted
outside. Recessed
installation
that is not exhausted
outside
must use Exhaust Deflector,
Part No. 3391278 (electric
dryer only),
available
from your dealer.
If dryer is installed
in a confined
area,
such as a bedroom,
bathroom
or
closet, it must be exhausted
to the
outside
and provision
made
for
enough
air for combustion
and
ventilation.
(Check
governing
codes
and ordinances.)
See "Recessed
area and closet installation
instructions"
on Page 11.
An exhaust
hood should cap the
exhaust
vent to prevent
exhausted
air
from returning
into the dryer. The
outlet of the hood must be at least
12 inches from the ground
or
anything
else that may be in the path
of the exhaust.
Four-inch
outlet hood is preferred.
However,
a 2-l/2-inch
outlet exhaust
hood may be used. A 2-l/2-inch
outlet creates
greater
back pressure
than other hood types. For
permanent
installation,
a stationary
exhaust
system is required.
A main exhaust
vent can be used for
exhausting
a group of dryers. Main
exhaust
vent should be sized to
remove
200 CFM of air per dryer.
Large-capacity
lint screens of proper
design
may be used in the main
exhaust
vent if checked
and
cleaned
frequently.
The room where
the dryers are located
should have
make-up
air equal
to or greater
than
the CFM of all the dryers in the room.
Back-draft
Damper
Kits, Part No.
3391910, are available
from your
Whirlpool
dealer
and should be
installed
in each
dryer's exhaust
vent
to prevent
exhausted
air from
returning
into the dryers and to keep
the exhaust
in balance
within the
main exhaust
vent. Unobstructed
air
openings
are required.
Page 2