Each exh'aust vent should enter the
main vent at an angle
pointing
in the
direction
of the aitilow. Vents entering
from the opposite
side should be
staggered
to reduce
the exhausted
air from interfering
with the other
vents.
The maximum
angle
of each vent
entering
the main vent should be no
more than 30".
Keep air openings
free of dry
cleaning
fluid fumes. Fumes create
acids which, when drawn through
the
dryer heating
units, can damage
dryers and loads being
dried.
A clean-out
cover should be located
on the main exhaust
vent for
periodically
cleaning
the exhaust
system.
An exhaust
hood should cap the
outside
end of the main vent to
prevent
exhausted
air from returning
to the dryers
If an exhaust
hood
cannot
be used, the outside
end of
the main vent should have a sweep
elbow
directed
downward.
If the
main vent travels vertically
through
the roof, rather than through
the wall,
install 180" sweep
elbow
on the end
of vent at least 2 feet above
the
highest
part of the building.
The
opening
wall or roof shall have a
diameter
l/2 inch larger than the
exhaust
vent diameter.
The exhaust
vent should be centered
in the
opening.
exhaust
hood or
l-l
R-
WOII
180"
2 ft. min. above
highest
point of
collector
vent
Do Not install screening
or cap over
end of vent.
Exhaust vent
connection
Determine
which
direction
you need
to attach
the exhaust
vent to the
dryer. Next, determine
the length
of
the exhaust
vent you will need to
connect
the dryer to exhaust
hood or
main vent.
To connect
exhaust
vent
straight
out the back
-
Attach
exhaust
vent to dryer vent.
Then connect
exhaust
vent to
exhaust
hood or main exhaust
vent
Use duct tape
to seat all joints.
This dryer may be converted
to be
exhausted
out the right or left side or
through
the bottom.
To convert
the
dryer, one of the following
kits MUST
be used:
Exhaust Kit No. 279818 (White)
Exhaust Kit No. 279819 (Almond)
Follow the instructions
in the kit to
avoid operational
and personal
hazard.
Gas supply
requirements
WARNING: If the
information in this manual
is not followed exactly, a
fire or explosion may result
causing property damage,
personal injury or death.
- Do not store or use
gasoline, or other
flammable vapors and
liquids in the vicinity of
this or any other
appliance.
- WHATTO DO IF YOU SMELL
GAS:
l
Do not try to light any
appliance.
l
Do not touch any
electrical switch; Do noi
use any phone in your
building.
l
Immediately call your
gas supplier from a
neighbor's phone.
Follow gas supplier's
instructions.
l
If you cannot reach your
gas supplier, call the firt
department.
-
Installation and service
must be done by a
qualified installer, service
agency or the gas
supplier.
Observe
all governing
codes and
ordinances.
Post this warning
in a prominent
location.
It is recommended
that the operator
post, in a prominent
location,
instructions
for the customer's
use in
the event the customer
smells gas.
This information
should be obtained
from your local gas supplier.
Page 3