6.3 Initial Setting or Previous Setting Modification Instructions

Remove the top cap (Fig. 1 A) using a 34mm fork spanner holding the tube with the hand
(Fig. 1 B). Check condition of O-ring (Fig. 2 E), and replace it if necessary, applying grease
on it.
Set the dip-switches to calibrate the current (Fig. 2 C, 4 switches) and set counting
operations (Fig. 2 D, 2 switches) using a small screwdriver according to table 1 settings.
Note: handle with care without damaging the switches. Settings must be made in a clean
and dry environment.