Using the BT-LFA Incandescent Light Fixture Adapter (BT-250 only)
1. Remove the light bulb exercising the proper caution.
2. Screw in the BT-LFA adapter.
3. Plug the Transmitter into the BT-LFA (Figure 3).
4. Preform scan following directions in step 4 under "Operation."
Using the BT-VLA High Voltage Leads Adapter (BT-250 only)
The BT-250 Transmitter can be used alone on 110V circuits. For circuits up to
250V or exposed circuits, use the BT-VLA and follow the directions listed below.
1. Plug Transmitter into high voltage lead receptacle. Be sure that the
Transmitter is completely seated and that no part of the Transmitter
prongs are exposed.
2. Attach the high voltage leads to the terminal or conductor while
exercising extreme caution (Figure 4).
3. Preform scan following directions in step 4 under "Operation."