Wiring Diagrams Standard Motor)
Please Note: Do not wire motors in parallel.
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green/Yellow (Ground)
Dashed wiring
by electrician
Control
Single gang box by others
1
7
switch
Min. 4" x 2
/
" x 1
8
Blue
Red
Black
Location of key
operated on-off
switch if furnished
To 110-120V Line
CAUTION: Wall switches
provided with these screens are
interior switches, and should
not be installed outdoors.
External Low Voltage and Remote Control
Do not wire motorized units in parallel without written consent from Draper.
Multiple Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green/Yellow (Ground)
Cap off with wire
nut and tape
Red
Blue
/
" deep
8
Black
Red
Blue
Black
Red
Blue
Single gang box by others
Black
Min. 4" x 2
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110-120V Line
www.draperinc.com
Wiring Diagrams
Dashed wiring
by electrician
1
/
" x 1
7
/
" deep.
8
8
External Two-Way Serial Communication (RS232) with MC1
White-Common to screen & 110-120V AC Neutral
Red-to Screen (directional)
Brown-to Screen (directional)
Black-Hot to 110-120V AC
Program LED
Green/Yellow-Ground
Fuse
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
Eye Port for IR Eye. For RF Receiver or LED
MC1
Wall Switch, a Splitter and a Power Supply
is required. Plug RF Receiver or LED Wall
Switch and Power Supply into splitter, then
run cable from Splitter to MC1 Eye Port.
(765) 987-7999
Radio Technology
110-120V Motor
Internal Screen Wiring
White (Neutral)
Black
Green (Ground)
Dashed wiring
by electrician
Wall Switch
or RF
Receiver
To 110-120V Line
Low Voltage Wiring by others
AC Wiring by electrician
Page 3 of 4
Internal Screen Wiring
White (Common)
Red (Up)
Black (Down)
Green/Yellow (Gnd)
To
110-120V
Line
STOP
Location of key
operated on-off
switch if furnished
STOP
Control
Switches