水ポンプ ComNav 15CIのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。ComNav 15CI 11 ページ。 Reversing motor pumpset
HYDRAULIC CONNECTIONS FOR TWO LINE STEERING SYSTEMS
A simple schematic of the pump installation is shown in Figure 2.
Delivery Lines:
Ports A and B in the diagram above are
the input/output ports of the pump and
must be connected to the steering lines
coming from the steering cylinder. It does
not matter which pump port is connected
to which steering line.
The compensating line MUST have a gradual rise from the pump to the connection to the
steering system. This allows air to rise out of the pump, ensuring a constant supply of oil to the
pump.
29010015V1.0(15CI & 25CI Pumps).doc
2 Line Steering System Installation
Compensating Line:
4
In the above diagram Port C is the
compensating or bleed line, and must be
connected to the steering system's
reservoir. This connection can be made
at a helm pump, remote reservoir (if there
is one), the compensating line connecting
two helm pumps, or the compensating
line connecting a helm pump to the
remote reservoir. If the connection is
being made directly to the helm pump,
ensure that the bleed line is connected to
the LOWER helm bleed port.