Ideally weld the mounting plate provided to the steel post and use extra strengthening brackets if
necessary to ensure a solidly fixed mounting plate (i.e. strengthening brackets may be required if post
is less than approximately 150mm wide).
If mounting to masonry or similar, either drill holes or weld tags onto the mounting plate or as a last
resort fix the operator straight to the wall preferably using suitable chemical type anchors to ensure a
firm mounting is obtained.
If fixing without mounting plate ensure spacers (i.e. washers or nuts) are used between the wall and the
operator to allow for the cover to fit.
Lift operator into position and bolt to the mounting plate.
Turn the knurled disc anticlockwise and position arms so they are approx. 10
when gate is fully closed.
o
off of being straight