- ページ 6

農機具 CenturionPro XL MEGABUCKERのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。CenturionPro XL MEGABUCKER 12 ページ。

HEMP & CANNABIS
HARVESTING
SOLUTIONS
FIXED SPEED CONVEYOR OPERATION
• The two fi xed speed conveyors for fl ower and stem/shoot extraction are powered by a
single 15amp circuit breaker on the main power panel, shown in fi gure 1. When power is
applied and this circuit breaker is on, the fi xed speed conveyors will start automatically and
run continuously for as long as the main power switch is engaged. Unplugging the machine,
turning off the main power switch (power lockout) or turning off the 15amp circuit breaker will
shut off the fi xed-speed conveyors. Note: the 15amp circuit breaker is for overload/emergency
protection only and should not be used as an "on/off " switch for the fi xed speed conveyors.
VARIABLE SPEED CONVEYOR OPERATION
• Like the two fi xed speed conveyors, the variable speed conveyor is powered by its own 15amp
circuit breaker and will run in accordance with the settings of the variable speed control unit,
located in the forward operator control box (see fi gure 2). This unit provides controls for
both speed and direction of the variable speed conveyor, allowing for fast or slow belt speed in
accordance with the number of operators present and their respective workload.
• To START the variable speed conveyor, momentarily press the RUN button and the variable
speed conveyor will begin to accelerate to its presently set speed.
• To INCRESE the speed of the conveyor, press and hold the UP arrow until the desired speed is
reached on the display panel (note: the conveyor speed may lag slightly behind the indicated
speed on the display panel, as the conveyor cannot speed up as quickly as the numbers on the
display). The indicated speed numbers allow for a reference that can be used to recreate belt
speeds which work for best effi ciency with a given number of operators and material types.
• To DECREASE the speed of the conveyor, press and hold the DOWN arrow until the desired,
reduced speed of the conveyor is met. The conveyor will slow down more quickly than it speeds
up and the indicated speed will more closely match the actual speed during deceleration.
• To REVERSE the direction of the conveyor belt, momentarily press and release the R/F direction
button and then momentarily press and release the M input button. The belt direction can
be changed when the conveyor is either stopped or running. If the conveyor is running, it
will quickly slow down and then accelerate again in the reversed direction. To reinstate the
previous direction, repeat the outlined steps above.
• For further information regarding the use, programming and troubleshooting of the variable
speed conveyor belt, see the supplied manufacturers manual packed inside of the forward
operator control box of the machine from the factory.
6
1 855 535 0558
ROLLER MOTOR OVERVIEW & REPLACEMENT
The motors used for powering the rollers are an advance design with integral power supply and
factory programmed control module. These motors are not designed to be user serviceable and
the included fi rmware is proprietary to the machine and manufacturer. Alterations will void the
warranty and may result in severe injury or death. End user service should be limited to the
removal and replacement of the motor and gearbox only. Neither the manufacturer nor its agents
or representatives assume responsibility for improperly assembled components or alterations
made to the original design or manufacturer of the machine after service has been performed.
If you have any questions, we recommend you consult a certifi ed electrical technician to do this
FIGURE 1
job for you.
MAIN POWER PANEL
& CIRCUIT BREAKERS
STEPS TO REPLACE THE MOTOR
1. Lock out the main power switch and unplug the machine from the power source.
MAIN POWER SWITCH
2. Remove the main motor cover and chain guards as needed for access.
& POWER LOCK-OUT
3. It will be necessary to slacken the tension on the drive chain via the chain adjuster sprocket
4. Remove the auxiliary cooling fan from the back of the motor via the four #__ torx head screws.
5. The clear plastic cover on the bottom of the motor must be removed via the four #__ torx
6. With the cover removed, the three main power wires must be removed by loosening the two
7. Unplug the blue cable from its respective connection port by squeezing the unlock lever and
8. The two bulkhead connection nuts must be loosened and removed and the wiring withdrawn
9. The four 3/8" bolts securing the gearbox/motor assembly to the machine may now be removed
10. With the motor removed, it may be separated from the gearbox assembly by removing the
11. If necessary, the chain drive sprocket can be removed from the gearbox by using an X/X hex
12. Reassembly is the reverse of removal, with the following important points noted.
• Be sure to replace and center all keys within their respective keyways before tightening securing
• The chain drive sprocket must be aligned with the other three sprockets over which the chain
FIGURE 2
VARIABLE SPEED
CONVEYOR CONTROL
UNIT
ROLLER SPEED
CONTROL KNOB
EMERGENCY STOP
SAFETY SWITCH
cprosolutions.com
GENERAL OPERATIONS
(see fi gure 3).
It is not necessary to disturb any wiring to the auxiliary fan.
head screws.
clamp screws and ground connection shown in fi gure C.
pulling it from the port.
from the motor.
and the motor lifted off the machine. Care must be taken, as the motor/gearbox assembly is
very heavy and diffi cult to handle. Additionally, the drive chain will still be engaged to the drive
sprocket on the end of the gearbox and must be lifted off prior to the motor being removed.
four 3/8" bolts from around the periphery of the gearbox to motor junction.
wrench to loosen the securing set-screw and withdrawing the sprocket from the output shaft.
screws or bolts.
rides to keep the chain riding true and without binding. This should be done after securing the
gearbox to the machine and before securing the sprocket to the shaft via the X/X set screw.