Warning:
Never use needles, wires, or similar cylindrical objects to clean
the pilot to avoid damaging the calibrated ruby that controls the
gas flow.
Thermostat Operation
To ignite main burner, turn gas control knob counterclockwise toward
HI setting. To shut down main burner, turn gas control knob clockwise
toward LO setting.
The SR-10T has an input of 10,000 BTUH (2.9KW/H). The hydrau-
lic thermostat bulb is located at the casing assembly bottom. When
the hydraulic thermostat bulb senses the need for heat, the unit cycles
"ON" at a full input rate of 10,000 BTUH (2.9KW/H). The unit
remains at this full input rate until the hydraulic thermostat bulb is
"satisfied." When the hydraulic thermostat bulb is "satisfied" the
burner will shut "OFF" with the pilot flame remaining "ON."
The SR-18T has an input of 18,000 BTUH (5.3KW/H). The hydrau-
lic thermostat bulb is located at the casing assembly bottom. When
the hydraulic thermostat bulb senses the need for heat, the unit cycles
"ON" at a full input rate of 18,000 BTUH (5.3KW/H). The unit
remains at this full input rate until the hydraulic thermostat bulb is
"satisfied." When the hydraulic thermostat bulb is "satisfied" the
burner will shut "OFF" with the pilot flame remaining "ON."
Note: The burner does not modulate between "ON" and the pilot
flame. When the SR-18T is "ON," all three ceramic plaques will
"glow." There will never be a time when only one or two ceramic
plaques are "glowing."
The SR-30T has an input of 30,000 BTUH (8.8KW/H). The hydraulic
thermostat bulb is located at the casing assembly bottom. When the
hydraulic thermostat bulb senses the need for heat, the unit cycles "ON"
at a full input rate of 30,000 BTUH (8.8KW/H). The unit remains at this
full input rate until the hydraulic thermostat bulb is "satisfied." When
the hydraulic thermostat bulb is "satisfied" the burner will shut "OFF"
with the pilot flame remaining "ON."
Note: The burner does not modulate between "ON" and the pilot flame.
When the SR-30T is "ON," all five ceramic plaques will "glow." There
will never be a time when only one or three ceramic plaques are
"glowing."
The LO and HI setting has temperature range of approximately 55°F
(12.78°C) to 90°F (32.22°C), respectively. This is the temperature at the
hydraulic thermostat bulb not the room temperature. The owner is
advised to determine the particular heat setting that is desired for
comfort, as heating requirements are different for every owner.
Attention: If the owner does not want the main burner to ignite and
turns the gas control knob to the LO setting, the main burner will still
ignite if the temperature at the hydraulic thermostat bulb drops to 55°F
(12.78°C).
If no heat is desired, turn the gas control knob to the PILOT position.
Main Burner Operation
Description of Gas Control Knob:
OFF position.
PILOT position.
LO/HI will allow the hydraulic thermostat bulb to cycle the heater ON
and OFF.
Page 10
Service Notes
R-5210