- ページ 9
スイッチ Dell Brocade VDX 6940のPDF 設定マニュアルをオンラインで閲覧またはダウンロードできます。Dell Brocade VDX 6940 12 ページ。 Ps series

2.11
Enable link level flow control (802.3x)
sw0(conf-if-te-1/0/1:1-4)# qos flowcontrol tx off rx on
sw0(conf-if-te-1/0/1:1-4)# exit
Reminder: Perform these steps on the other 4 x 10 edge ports.
2.12
Configure spanning tree on edge ports
sw0(config)#protocol spanning-tree rstp
sw0(config-rstp)#exit
sw0(config)# interface TenGigabitEthernet 1/0/1:1-4
sw0(conf-if-te-1/0/1:1-4)# spanning-tree edgeport
Reminder: Perform these steps on the other 4 x 10 edge ports.
2.13
Disable LLDP iSCSI priority on switch ports
sw0(conf-if-te-1/0/1:1-4)# no lldp disable
sw0(conf-if-te-1/0/1:1-4)# no cee
sw0(conf-if-te-1/0/1:1-4)# no lldp iscsi-priority
sw0(conf-if-te-1/0/1:1-4)# end
Reminder: Perform these steps on the other 4 x 10 edge ports.
2.14
Save configuration
Sw0# copy running-config startup-config
This operation will modify your startup configuration. Do you want to continue?
[y/n]:y
2.15
Configure additional switch
Repeat the commands from sections 2.1 through 2.14 to configure the second switch.
9
Brocade VDX 6940 Switch Configuration Guide for Dell PS Series SANs | SCG3306