Dell Brocade VDX 6940 Podręcznik konfiguracji - Strona 9

Przeglądaj online lub pobierz pdf Podręcznik konfiguracji dla Przełącznik Dell Brocade VDX 6940. Dell Brocade VDX 6940 12 stron. Ps series

Dell Brocade VDX 6940 Podręcznik konfiguracji
2.11

Enable link level flow control (802.3x)

sw0(conf-if-te-1/0/1:1-4)# qos flowcontrol tx off rx on
sw0(conf-if-te-1/0/1:1-4)# exit
Reminder: Perform these steps on the other 4 x 10 edge ports.
2.12

Configure spanning tree on edge ports

sw0(config)#protocol spanning-tree rstp
sw0(config-rstp)#exit
sw0(config)# interface TenGigabitEthernet 1/0/1:1-4
sw0(conf-if-te-1/0/1:1-4)# spanning-tree edgeport
Reminder: Perform these steps on the other 4 x 10 edge ports.
2.13

Disable LLDP iSCSI priority on switch ports

sw0(conf-if-te-1/0/1:1-4)# no lldp disable
sw0(conf-if-te-1/0/1:1-4)# no cee
sw0(conf-if-te-1/0/1:1-4)# no lldp iscsi-priority
sw0(conf-if-te-1/0/1:1-4)# end
Reminder: Perform these steps on the other 4 x 10 edge ports.
2.14

Save configuration

Sw0# copy running-config startup-config
This operation will modify your startup configuration. Do you want to continue?
[y/n]:y
2.15

Configure additional switch

Repeat the commands from sections 2.1 through 2.14 to configure the second switch.
9
Brocade VDX 6940 Switch Configuration Guide for Dell PS Series SANs | SCG3306