Dell Brocade VDX 6940 Configuratiehandleiding - Pagina 9

Blader online of download pdf Configuratiehandleiding voor {categorie_naam} Dell Brocade VDX 6940. Dell Brocade VDX 6940 12 pagina's. Ps series

Dell Brocade VDX 6940 Configuratiehandleiding
2.11

Enable link level flow control (802.3x)

sw0(conf-if-te-1/0/1:1-4)# qos flowcontrol tx off rx on
sw0(conf-if-te-1/0/1:1-4)# exit
Reminder: Perform these steps on the other 4 x 10 edge ports.
2.12

Configure spanning tree on edge ports

sw0(config)#protocol spanning-tree rstp
sw0(config-rstp)#exit
sw0(config)# interface TenGigabitEthernet 1/0/1:1-4
sw0(conf-if-te-1/0/1:1-4)# spanning-tree edgeport
Reminder: Perform these steps on the other 4 x 10 edge ports.
2.13

Disable LLDP iSCSI priority on switch ports

sw0(conf-if-te-1/0/1:1-4)# no lldp disable
sw0(conf-if-te-1/0/1:1-4)# no cee
sw0(conf-if-te-1/0/1:1-4)# no lldp iscsi-priority
sw0(conf-if-te-1/0/1:1-4)# end
Reminder: Perform these steps on the other 4 x 10 edge ports.
2.14

Save configuration

Sw0# copy running-config startup-config
This operation will modify your startup configuration. Do you want to continue?
[y/n]:y
2.15

Configure additional switch

Repeat the commands from sections 2.1 through 2.14 to configure the second switch.
9
Brocade VDX 6940 Switch Configuration Guide for Dell PS Series SANs | SCG3306