can be removed from the system to eliminate it from the suspect list until root
cause is found.
Note that if the ME is disabled, then all AMT functions are also disabled. The
system will not be remotely manageable.
6.
Check Password Policy.
Default Setting
Recommended Setting
a.
Select Default Password Only
This option determines when the user is allowed to change the Intel MEBX
password through the network. The Intel MEBX password can always be
changed via the Intel MEBX user interface.
Default Password Only – The Intel MEBX password can be changed through the
network interface if the default password has not been changed yet.
During Setup and Configuration – The Intel MEBX password can be changed
through the network interface during the setup and configuration process but at no
other time. Once the setup and configuration process is complete, the Intel MEBX
password cannot be changed via the network interface.
Anytime – The Intel MEBX password can be changed through the network interface
at any time
7.
Network Setup.
Figure 3: Intel ME Network Name Settings Screen
: Default Password Only
: Default Password Only
7