- ページ 7

温度コントローラー dicodes Dani Extreme V2+のPDF マニュアルをオンラインで閲覧またはダウンロードできます。dicodes Dani Extreme V2+ 12 ページ。
dicodes Dani Extreme V2+ にも: マニュアル (12 ページ)

05 Main Menu (Page 4)
Switch Off Device
Beside the Auto-Power-Off feature, the user can actively switch off the device. It is
recommended to switch the device off or to wait for auto-power-off, before the battery
is replaced, because then the statistic counters (see below) are saved. Otherwise the
changes since the last power up are lost.
To switch off the device wait on this menu item until the display of the 0 is inverted,
the press the button.
Extended Functions Menu
The Extended Functions Menu provides three logically grouped sub-menues:
Heater Menu
Mod Menu
Value Menu
The Extended Functions Menu offers a lot of setting options of the mod, to provide
the highest possible flexibility for the user to individually adjust it to whatever pre-
ferences. Normally, once the settings were made, the user will need to change the
parameter rarely. In order to keep the main menu as short as possible, the extended
functions menu was created.
The many options may frighten some of the users initially. But without the extended
functions menu the mod would not be able to address all different customer require-
ments. Please take a bit of time to get familiar with the menu. We are sure, as soon
as you have gained an overview, the individual setup is a walk-over.
Error Messages
If an error occurs, the mod directly jumps to the error menu and displays the error
number and a mnemonic (short-term) description.
The possible error messages are:
0 OvrVolt:
1 ChkAtom: No atomizer detected or open coil.
2 TempRef: A problem during the temperature reference measurement occured
3 HighR:
4 OverCur: Short on coil or coil breakdown (open)
5 LowBat:
6 EleHot:
7 TimeOut: The maximum puff-time is limited depending on power. For a power <20W
8 LowR:
Settings related to the heater or coil
Settings related to the individual usage and appearance
Provides several statistics of vaping
The input voltage is too high. The DaniExtreme V2 is prepared for the
use of one battery. If the input voltage exceeds 4.5V this error message
is displayed. Reduce the input voltage to the specified range.
The resistance of the coil is too high for the selected output power. The
maximum output voltage is 12V and current is 15A. This specification
together with a maximum output power of 40W leads to a resistance
range of 0.2-3.5 Ohms. Also see "8 LowR". Higher and lower resistances
are possible, but the power has to be reduced accordingly.
Example 1: With a 4Ohm coil the maximum power is (12V)²/4 Ohm=36W.
Example 2: With a 0.12Ohm coil the maximum power is (15A)²*0.12 Ohm
= 27W. Note that for resistances >3.5 Ohm the ouput voltage is the limiting
factor, whereas for resistances <0.2 Ohms it is the current.
The battery voltage under load (with current drained from it) has reached
the minimum discharge level, defined with parameter UbatMin in the
extended function mod-menu.
The electronics have heated up too much and needs to cool down. This
error will not occur with normal usage of the mod.
it is 20seconds. Above 20W it decreases by 0.5seconds per Watt.
The coil resistance is too low for the selected power, please see "3 HighR".