- ページ 7
ネットワーク・ハードウェア Cisco Firepower 4100 SeriesのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Cisco Firepower 4100 Series 8 ページ。 Rack-mount and ground the chassis
Cisco Firepower 4100 Series にも: 製品マニュアル (17 ページ), メンテナンスとアップグレードマニュアル (20 ページ), マニュアル (36 ページ), マニュアル (8 ページ), マニュアル (42 ページ), マニュアル (38 ページ)
Rack-Mount the Chassis
Step 1
Use a wire-stripping tool to remove approximately 0.75 in. (19 mm) of the covering from the end of the grounding cable.
Step 2
Insert the stripped end of the grounding cable into the open end of the grounding lug.
Figure 5: Insert the Cable into the Grounding Lug
Step 3
Use the crimping tool to secure the grounding cable in the grounding lug.
Step 4
Remove the adhesive label from the grounding pad on the chassis.
Step 5
Place the grounding lug against the grounding pad so that there is solid metal-to-metal contact, and insert the 2 screws
with washers through the holes in the grounding lug and into the grounding pad.
Step 6
Make sure that the lug and cable do not interfere with other equipment.
Step 7
Prepare the other end of the grounding cable and connect it to an appropriate grounding point in your site to ensure
adequate earth ground.
What to do next
Install the cables according to your default software configuration as described in the
for your version.
• Two 10-32 x .375-in. screws used to secure the ground lug
Ground the Chassis
Getting Started Guide
Rack-Mount the Chassis
7