back panel of the cooker could reach a temperature of
50°C above room temperature. For proper installation of
the cooker, the following precautions must be taken:
a) The hob may be located in a kitchen, a kitonen/diner
or bed sitting room, but not in a bathroom or shower
room.
b) The furniture standing next to the unit, that is higher
than the working boards, must be placed at least 600
mm from the edge of the board.
c) The cabinets should be positioned next to the hood at
a height of at least 420 mm (Fig. C).
600mm min.
d) Should the hob be installed directly under a cupboard,
the letter should be at least 700mm (millimetres) from
the worktop, as shown in Fig. C.
e) The dimensions of the room for the furniture must be
those indicated in the figures in the last two pages of
the cover. Fixing hooks are provided which allow to
place the hob plate on work tops that measure from
20 to 40 mm in thickness (see Fig. D). To obtain a good
fixing of the hob plate it is advisable to use all the hooks
supplied.
55
mm
Hook position for
H=30mm top
Fig. C
555
mm
Fig. D
Hook position for
H=40mm top
Hook position for
H=20mm top
N.B: Use the hook contained in the "accessoires set"
f) The hob can only be installed above built-in ovens
provided with cooling ventilation.
g) In the event the cooktop is not installed above a built-
in oven, a wood panel must be inserted as insulation.
This panel must be placed at least 20 mm from the
bottom of the cooktop itself.
Important: When installing the hob above a built-in oven,
the oven should be placed on two wooden strips; in the
case of a joining cabinet surface, remember to leave a
space of at least 45 x 560 mm at the back.
Gas connection for gas hob
The cooker should be connected to the gas-supply by a
corgi registered installer. During installation of this product
it is essential to fit an approved gas tap to isolate the supply
from the appliance for the convenience of any subsequent
removal or servicing. Connection of the appliance to the
gas mains or liquid gas must be carried out according to
the prescribed regulation in force, and only after it is
ascertained that it is adaptable to the type of gas to be
used. If not, follow the instructions indicated in the
paragraph headed "Adaptation to different gas types". In
the case of connection to liquid gas, by tank, use pressure
regulators that conform to the regulation in force.
Important: For safety, for the correct regulation of gas
use and long life of the appliance, ensure that the gas
pressure conforms to the indications given in table 1
"Nozzle and burner characteristics".
Connection to non-flexible tube
(copper or steel)
Connection to the gas source must be done in such a
way as to not create any stress points at any part of the
appliance.
The appliance is fitted with an adjustable, "L" shaped
connector and a gasket for the attachment to the gas supply.
Should this connector have to be turned, the gasket must be
18