溶接システム Cutlass Fasteners LBS-075-TのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Cutlass Fasteners LBS-075-T 19 ページ。

Temperature: LED red...temperature
inside Classic exceeds 80ºC.
Chargeing cycles will be longer due to
the elevated temperature.
Main Switch: LED green...Classic is
switched on.
Power: LED green...Classic is
connected to power supply and
turned on.
Blocked: LED red...the gun has not
been withdrawn after welding stud.
Residual voltage may have been
greater than 36 volts.
The Main Switch and the following LED‟s must light up when CLASSIC is turned on...
a) Power LED
b) Capacitor charge LED...lights up red briefly and green when CLASSIC is ready.
c) Contact light...when stud in gun is touched to workpiece (grounds must be connected).
d) Hold the gun in the air and pull trigger...trigger LED should illuminate.
Solenoid light will not come on with PKM-1B connected. Solenoid light only illuminates
e)
when optional PHM-1A GAP weld gun is connected.
COPYRIGHT CFI 2009
Cutlass Fasteners, Inc.
83 Vermont Ave., Unit 6, Warwick, RI 02888
Tel: (401) 732-6333 Fax: (401) 732-6336
cutlass-studwelding.com
CLASSIC+ CD MANUAL

INDICATORS AND SYMBOLS

START CHECK
email:
Stud Welding...
Fasteners
Equipment
Service
Capacitor charge status:
LED red....capacitors charging. LED
green...capacitors charged.
LED off ...capacitors discharging.
Potentiometer: For setting capacitor
charge.
Trigger: LED green...trigger button is
pressed to start weld sequence.
Solenoid: LED orange...PHM-1A
weld gun is connected
Contact:: LED orange...complete
weld circuit...stud is connected to
workpiece.