- ページ 2
アクセサリー DOL 46RのPDF テクニカル・ユーザー・マニュアルをオンラインで閲覧またはダウンロードできます。DOL 46R 4 ページ。 Capacitive sensors
TECHNICAL USER GUIDE
PRODUCT DESCRIPTION:
DOL 46R is a capacitive relay sensor for
detection of feed, grain and solids. The
sensors have relay output including switch
function. Certified according to ATEX
directive 2014/34/EU and IECEx for
operation in potential explosive dust
atmospheres. Classified as high-level
equipment for use in atmospheres with
continuous presence of explosive dust with
an ignition temperature above 85 °C.
Fields of application:
• Level control in silos and containers
• Controlling the filling and emptying
process.
MOUNTING GUIDE (FIG. 1):
DOL 46R is made in a ø30 mm smooth
design mounted in a gland.
Figure 1
INSTALLATION GUIDE (FIG. 2):
Supply voltage is connected to the blue and
brown wire.
The load is connected in series with the
relay contact of the sensor.
STOP by activating the sensor: Use the
black wires 1 and 3.
START by activating the sensor: Use the
black wires 1 and 4.
NOTE! The internal relay is in position NC
when the supply voltage is connected and
the sensor is activated - wire 1 and 4 are
connected.
Figure 2: No-current sensor
dol-sensors a/s
Hedelund 4, Glyngøre
USER'S GUIDE:
•
Easy trimmer adjustment on a
single turn 240° trimmer with
linear or non-linear scale.
•
Functions which can be made
available for adjustment on
trimmers:
-
ON and/or OFF delay
-
MaxRunTimer
-
Sensitivity
DOL 46R has a red LED, indicating
sensor status and a green LED
indicating power on.
Fig. 3 shows examples of LED
sequences.
Figure 3
Relay NC (1-4)
Relay NO (1-3) after delay
LED- sequence
Sensor
No time
delay
Delayed
discon-
nection
Delayed
connec-
tion
7870 Roslev
Denmark
Tlf. +45 72 17 58 88
TECHNICAL DATA:
Supply voltage:
Voltage:
Frequency
Relay:
Max. resistive load,
250 VAC:
Max. inductive load,
250 VAC:
Min. relay current,
12 VDC
Temperature:
Temp.
operation:
Temp. storage:
Degree of protection:
IP:
NEMA:
Cable:
Length:
Conductor
dimensions:
Dimensions:
NC (1-4)
NO (1-3)
LED
NC (1-4)
NO (1-3)
LED
Approvals:
NC (1-4)
NO (1-3)
LED
ATEX zone 20, 21 and 22, dust
EN/IEC conforms to the Harmonized
standards
CE
0539
II 1D Exta IIIC T
Fax +45 72 17 59 59
20 - 280 V AC/DC
47 - 63 Hz
4 A
2 A
100 mA
- 30 °C - + 50 °C
- 22 °F - + 122 °F
- 40 °C - + 80 °C
- 40 °F - + 176 °F
69K
1, 3, 4, 6, 12, 13
2 m, 5 m or 10 m
6.6, 16.5 or 33 feet
2
5 x 0.5 mm
5 x AWG20
o
85
C Da
200
www.dol-sensors.com