- ページ 4
アクセサリー DOL 46RのPDF テクニカル・ユーザー・マニュアルをオンラインで閲覧またはダウンロードできます。DOL 46R 4 ページ。 Capacitive sensors
SPECIFIC CONDITIONS OF USE
FUNCTIONS AND FEATURES
•
Use in hazardous areas according to the classification
(group II, category IIIC, apparatus for dust atmosphere).
Complies with the requirements of the standards EN/IEC 60079-0 and EN/IEC 60079-31.
•
Label information
II 1 D Ex ta IIIC T
II: The sensor is classified for explosion group II, which concerns all remaining risk areas but mines
1: Category 1. The sensor can be used in zone:
20: Flammable material present continuously or long periods.
21: Flammable material present occasionally.
22: Flammable material present in abnormal conditions for short periods.
D: For use in hazardous areas, in which explosive dust are present.
Ex: Conforms to the Harmonized Standards.
ta: Protection by enclosure, highest level
IIIC: Conductive dust.
o
T
85
C: The max. surface temperature of the sensor, 85
200
Da: EPL Da. See Category 1 D above.
•
Permissible operating temperature of the application (proper usage):
Ta: -30°C...+50°C
MAINTENANCE / REPAIR
The unit must not be modified nor can it be repaired. In case of a fault please contact the manufacturer.
dol-sensors a/s
Hedelund 4, Glyngøre
o
85
C Da
200
7870 Roslev
Denmark
o
C.
Tlf. +45 72 17 58 88
Fax +45 72 17 59 59
www.dol-sensors.com