- ページ 4

アクセサリー DOL 46RのPDF テクニカル・ユーザー・マニュアルをオンラインで閲覧またはダウンロードできます。DOL 46R 4 ページ。 Capacitive sensors

SPECIFIC CONDITIONS OF USE
FUNCTIONS AND FEATURES
Use in hazardous areas according to the classification
(group II, category IIIC, apparatus for dust atmosphere).
Complies with the requirements of the standards EN/IEC 60079-0 and EN/IEC 60079-31.
Label information
II 1 D Ex ta IIIC T
II: The sensor is classified for explosion group II, which concerns all remaining risk areas but mines
1: Category 1. The sensor can be used in zone:
20: Flammable material present continuously or long periods.
21: Flammable material present occasionally.
22: Flammable material present in abnormal conditions for short periods.
D: For use in hazardous areas, in which explosive dust are present.
Ex: Conforms to the Harmonized Standards.
ta: Protection by enclosure, highest level
IIIC: Conductive dust.
o
T
85
C: The max. surface temperature of the sensor, 85
200
Da: EPL Da. See Category 1 D above.
Permissible operating temperature of the application (proper usage):
Ta: -30°C...+50°C
MAINTENANCE / REPAIR
The unit must not be modified nor can it be repaired. In case of a fault please contact the manufacturer.
dol-sensors a/s
Hedelund 4, Glyngøre
o
85
C Da
200
7870 Roslev
Denmark
o
C.
Tlf. +45 72 17 58 88
Fax +45 72 17 59 59