DoorHan PCB-SW 24 프로그래밍 지침 매뉴얼 - 페이지 18

{카테고리_이름} DoorHan PCB-SW 24에 대한 프로그래밍 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DoorHan PCB-SW 24 20 페이지.

DoorHan PCB-SW 24 프로그래밍 지침 매뉴얼
3.4. RESET TO FACTORY SETTINGS
For resetting of parameters to factory settings enter the advanced programming mode, select 9.8 item, press the P button. The
display will indicate rE, press and hold the P button for five seconds.
rE will stop flashing at the display, the board will reboot, and a short signal will sound. After the operation performed all the set-
tings will be set as DEFAULT.
NOTE.
Resetting to factory settings won't erase receiver memory.

4. REMOTE CONTROL PROGRAMMING

4.1. ERASE RECEIVER MEMORY
When power supply is switched on press and hold the R button for 10 seconds. A long signal will sound confirming
successful memory erasing.
4.2. RECORD DOORHAN REMOTE CONTROLS TO THE RECEIVER
Press and hold the R button to record remote controls. Wait till two zeros (00) appear on the display. Then on the
remote control press and release the button that you would like to program twice. A short signal will sound, confirming
successful recording, the display will show the number of recorded remote controls. Wait for automatic exit to the opera-
tion mode. Repeat code recording for each remote control if you wish to record several remotes. Thus up to 100 remote
controls can be recorded to the receiver memory.
NOTES.
ƒ If no control commands are given the receiver will automatically time out of remote control recording mode in
10 seconds.
ƒ After power supply of control unit is off the programmed data is stored in the memory.
ƒ If memory is full three long signals will sound.
4.3. PROGRAMMING OF REMOTE CONTROL BUTTONS
change the type of the command sent after button pressing:
To
1. Enter the advanced programming menu (see section 3.3).
2. Select a corresponding menu item (1.4–1.7, see table 3.2) depending on the number of the button (1...4) you wish to
program (see section 4.4).
3. Press «+» and «–» buttons to choose the control command type from 0 to 3 (see table 4.1).
4. Press the P button to save values.
5. Press the R button to exit programming mode.
Parameter
value
0
1
2
3
18
REMOTE CONTROL PROGRAMMING
Table 4.1. Control commands of the remote control buttons
Control command type
START command
PEDESTRIAN command
STOP command
OUT(n) command