Activate bit timing parameters
The new bit timing parameters are activated with the command specifier 15h.
7E5h  15h
Switch delay
Switch Delay
: Reset delay in the slave in ms.
After the delay, the sensor logs on with the new baud rate.
Request vendor ID
Requesting the vendor ID of a selected sensor
7E5h  5Ah
reserved
7E4h  5Ah
32 bit vendor ID
Vendor ID
: = ECh
Request product code
Request product code of a selected sensor
7E5h  5Bh
reserved
7E4h  5Bh
Product code
Product code
: Manufacturer-dependent product code
Request revision number
Request revision number of a selected sensor
7E5h  5Ch
reserved
7E4h  5Ch
32 bit revision number
Revision number : Current revision
Request serial number
Request serial number of a selected sensor
7E5h  5Dh
reserved
7E4h  5Dh
32 bit serial number
Serial number
: Unique consecutive serial number of the sensor
Baumer_GIM500R_CANopen_MA_EN.docx
03.19
reserved
reserved
reserved
reserved
reserved
20/29