Electrolux CH120 지침서 - 페이지 12

{카테고리_이름} Electrolux CH120에 대한 지침서을 온라인으로 검색하거나 PDF를 다운로드하세요. Electrolux CH120 21 페이지. Chimney hood
Electrolux CH120에 대해서도 마찬가지입니다: 지침서 (20 페이지)

Clearance Height
The cooker hood is designed to be fitted over a
cooking appliance at the clearance heights stated,
providing the maximum output of the appliance
beneath does not exceed the maximums quoted in
the Technical Specifications.
If the output of the appliance below the cooker
hood exceeds the maximum outputs quoted,
please refer to the cooker manufacturer's
installation instructions.
A minimum clearance height of 650mm
(25 1/2 ") is required when installed above a
built-in electric hob, or 700mm (27 1/2 ") when
installed above a built-in gas hob.
A minimum clearance height of 685mm (27")
is required when installed above a slot-in
electric cooker, or 787mm (30 1/2 ") when
installed above a slot-in gas cooker.
When installed between adjoining wall
cabinets, the wall cabinets must not overhang
the hob and the distance between the
underside of the cabinet and the worktop must
be 450mm. If the height of the wall cabinet is
less than 450mm, a gap of 50mm must be
maintained either side of the hob.
This cooker hood must not be installed above
a cooking appliance with a high level grill.

Fitting the Wall Brackets

1.
Draw a vertical line on the wall from the
centre of the cooking appliance up to the
ceiling, using a spirit level and marking pen.
This is to ensure the correct vertical
alignment of the appliance.
2.
Draw a horizontal line through the vertical
at 270mm. Mark the centre positions for
the lower bracket fixing screws (1) at
110mm either side of the vertical line (screws
not supplied).
Ensure that the distance between the
lowest point of the hood and the cooking
appliance beneath meet the clearance
requirements quoted above.
3.
Draw a horizontal line through the vertical
at 45mm from the ceiling or from the
maximum height of the chimney. Mark the
centre positions for the upper bracket
fixing screws (2) at 80mm either of the
vertical line (screws not supplied).
A: Built-in Electric Hob:
B: Built-in Gas hob:
C: Slot-in Electric Cooker: 685mm minimum clearance
D: Slot-in Gas Cooker:
12
Hob
650mm minimum clearance
700mm minimum clearance
787mm minimum clearance
2
3
1