ANSMANN POWERLINE 5 PRO 매뉴얼 - 페이지 4
{카테고리_이름} ANSMANN POWERLINE 5 PRO에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ANSMANN POWERLINE 5 PRO 5 페이지.
ANSMANN POWERLINE 5 PRO에 대해서도 마찬가지입니다: 매뉴얼 (20 페이지)
USING THE CHARGER IN A VEHICLE
Connect the DC charging cable to the charger. Connect the DC
charging cable to the 12V DC car socket of your vehicle (Do not
use in 24V DC truck sockets!). Please make sure that the power
of the socket is switched on. Some cars require the ignition to be
switched on.
The charger is now ready for use. You can insert one 9V E-block
and up to 4 AA/AAA/C/D (in any combination) NiMH or NiCd rechar-
geable batteries. You can also connect an USB cable using the
USB charging socket to charge other devices, for example; mobile
phone, smart phone or MP3 player. Insert all batteries with correct
polarity, corresponding to the symbols in the charging slot.
CHARGING OF ROUNDCELLS
The charger has 3 function buttons; "CURRENT", "DISPLAY" and
"MODE" (see illustration [2A]). Using these buttons, it is possible
to use the following settings:
1. MODE button
Push the "MODE" button within 8 seconds of inserting 1-4
rechargeable batteries, to access one of the following charging
programs:
a. CHARGE: Charges battery. After charging is complete, charger
will automatically switch to trickle charging (Trickle charge
will commence after all modes)
b. DISCHARGE: Discharges battery before charging to minimize
the "memory effect" of batteries
c. REFRESH: "DISCHARGE REFRESH" or "CHARGE REFRESH" status
is shown on the LCD display when charger cycles between
discharging and charging. This process will refresh old bat-
teries and bring them back to the maximum capacity. Refresh
will be repeated (max. 10x) until the charger can no longer
register a rise in capacity.
d. TEST: Fully charges battery. LCD display shows "CHARGE TEST"
Discharges battery and measures capacity. The LCD display
shows "DISCHARGE TEST". Recharges battery, ready for use.
LCD display shows "CHARGE TEST".
2. CURRENT button
Push the "CURRENT" button within 8 seconds of selecting a char-
ging program or after inserting batteries in order to select the
charging current for the program "CHARGE" or "TEST". Alternati-
vely, choose the discharging current for the program "DISCHARGE"
or "REFRESH".
3. DISPLAY button
Push the "DISPLAY" button whilst charging or discharging to
display the charging/discharging current (mA), the voltage of the
rechargeable battery (V), the charging/discharging capacity (mAh
or Ah) or the remaining charging/discharging time (hh:mm).
Deutsch |
Italiano | Nederlands | Dansk | Slovenščina | Čeština | Slovenský | Polski
English
| Français | Pусский | Español | Português | Svenska
Once the settings have been selected, the charger automati-
cally starts with the selected parameters after 8 seconds. If no
settings are chosen, the LCD display will flash after inserting
the rechargeable batteries. First the voltage of the rechargeable
batteries as well as the pre-set charging program "CHARGE" is
shown. Next, the pre-set charging current of 600mA is shown.
After 8 seconds the charging process starts automatically using
the pre-set parameters.
By using the 4 charging slot buttons (see illustration [2B]) you
can make individual settings for each rechargeable battery. To
change a function for a single rechargeable battery, press the
corresponding button below the charging slot for the chosen
battery. The display will flash for this battery and you can now
change settings, as described above, for the single charging slot
using the function buttons "MODE" and/or "CURRENT".
If only one or two rechargeable batteries are inserted into the
charger using the two outer charging slots, in the mode "CHARGE"
and "TEST" the charging current can be increased up to 1500mA
or 1800mA with the "CURRENT" button. In this case the inner
charging slots are disabled and cannot be used. When charging
three or four rechargeable batteries at the same time, the
charging current can be set to 400mA, 600mA or 800mA. Using
the programs "DISCHARGE" and "REFRESH" discharging currents of
200mA, 300mA or 400mA can be selected. The charging current is
generally twice as high as the chosen discharging current.
A few minutes before the rechargeable batteries are completely
charged, the charger reduces the charge current to ca. 200mA,
regardless of the previously selected charge current. This gentle
full-charging extends the service life of your rechargeable
batteries.
After every charge/discharge procedure is complete, the charger
adds a short pause for the benefit of the rechargeable batteries
before continuing with the selected charging/discharging
program.
ATTENTION: Please ensure that the rechargeable batteries are
designed for the respective charging current. For example, AAA
rechargeable batteries should not be charged with a 1500mA or
1800mA charging current! We recommend choosing the maximum
charging current (mA) so that it does not exceed the capacity
value (mAh) of the inserted rechargeable battery.
It is normal that batteries may become warm during charging.
After charging is complete, the charger switches automatically to
trickle charge. The trickle charge prevents self-discharge of the
batteries when left in the charger.