Fitting Instruction for Remaining Thread Monitor
2.2 Connecting the cables and hoses
Ausgabe/Edition:
Änderungsindex
03.2011
Rev. index: 00.0
Anbauanleitung Restfadenwächter
Teilesatz 0911 597754
Kit 0911 597754
–
Conduct the light barrier cable, the cable 9870 911017 (up to
the cable harness after modification status 9870 911003_2.0)
and the air hose through the bore on the base plate and attach
them with cable binders to the existing harness (consisting of
cables, pneumatic and lubrification hoses).
–
Conduct the cables to the right out of the machine arm to the
console on the right.
–
Conduct the air hose to the left out of the machine arm to the
console on the left.
–
If there is no plug connector X632 on the right console (up to
the cable harness after modification status 9870 911003_02.0):
Connect the cable 9870 911017 with the flat plugs onto the
clamp X552 on the base plate as follows (also compare
connection diagram 9890 911003 B):
white to 3
yellow to 4
green to 5
brown to 6
–
Connect the cable 9870 911018 with the adapter plug 1
(X100b) to the control unit.