Configuration
6. Identify the USB Serial Port assignment by checking Control panel > System > Hardware >
Device Manager> Ports (COM & LPT).
N.B.!:
If the USB port is not shown, disconnect then reconnect the cable. If the problem
persists, restart your PC.
7. Open WinMaster and change the Network Settings to:
Protocol:
Baud rate:
Serial Port:
8. Apply control voltage to the soft starter. Bring WinMaster on-line, then Search for Network
Starters.
N.B.!:
The starter may trip on Starter Comms while the Master is off-line. Reset the soft starter
and place the Master on-line.
N.B.!:
The drivers will configure the USB port that the module is connected to. You must use
the same physical USB port every time you connect the module to the PC.
AP Binary or AP ASCII
9600
Use the serial port number identified above
MI.17.C1.02 - VLT
®
is a registered Danfoss trademark
MCD USB Module Instructions
4