BENDIX AD-IS - 매뉴얼 - 페이지 14
{카테고리_이름} BENDIX AD-IS -에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. BENDIX AD-IS - 17 페이지. Air dryer and reservoir system
BENDIX AD-IS -에 대해서도 마찬가지입니다: 브로셔 (2 페이지), 서비스 데이터 (15 페이지)
- 1. Air Dryer/Reservoir System Charge Cycle
- 2. Air Dryer/Reservoir System Purge Cycle
- 3. Charge Cycle
- 4. Purge Cycle
- 5. Preventive Maintenance
- 6. Operation & Leakage Tests
- 7. Pressure Protection Valve Locations
- 8. Testing
- 9. Braking System Protection & Inspection
- 10. Temporary Air Dryer/Reservoir System Bypass
- 11. Delivery Check Valve Cleaning Procedure
- 12. Cleaning and Inspection
- 13. Troubleshooting
SYMPTOM
5. Cannot build system air
pressure.
6. Air dryer does not purge
or exhaust air.
7. Desiccant material
being expelled from air
dryer purge valve
exhaust (may look like
whitish liquid or paste
or small beads.)
8. Unsatisfactory
desiccant life.
9. "Pinging" noise
excessive during
compressor loaded
cycle.
14
TROUBLESHOOTING CHART (Continued)
CAUSE
A. Kinked or blocked
(plugged) discharge line.
B. Excessive bends in
discharge line (water
collects and freezes).
C. Pressure protection
valve(s) in air dryer will
not open.
D. Refer to Symptom 4.
E. Refer to Symptom 7.
A. Faulty air dryer purge
valve.
B. See Causes B, E, and F
for Symptom #4.
A. Faulty dryer cartridge.
B. Excessive dryer vibration.
A. Excessive system
leakage.
B. Wrong vehicle application
for AD-IS
®
air dryer.
C. Compressor passing
excessive oil.
A. Single cylinder
compressor with high
pulse cycles.
REMEDY
A. Check to determine if air passes through discharge
line. Check for kinks, bends, excessive carbon
deposits, or ice blockage.
B. Discharge line should be constantly sloping
from compressor to air dryer with as few bends as
possible.
C. Replace air dryer (pressure protection valves are
not serviceable).
D. Refer to Symptom 4, Remedy A.
E. Refer to Symptom 7, Remedies A and B.
A. After determining air reaches purge valve control
port by installing a T-fitting with a pressure gauge
into the governor unloader port, repair purge valve
if necessary.
B. Refer to Symptom 4, Remedies B, E, and F.
Also refer to Symptom 1, Remedy B.
A. Replace AD-IS
®
air dryer cartridge and/or AD-IS
air dryer.
®
B. Check the AD-IS
air dryer mounting for looseness
or damage. Repair mounting and replace cartridge.
A. Refer to Symptom 1, Remedy A.
B. Refer to Symptom 2, Remedy C.
C. Check for proper compressor installation; if
symptoms persist, replace compressor. Refer to
Bendix Advanced Troubleshooting Guide for Air
Brake Compressor (BW1971).
A. A slight "pinging" sound may be heard during
system build up when a single cylinder compressor
is used. If this sound is deemed objectionable, it
can be reduced substantially by increasing the
discharge line volume.
This can be accomplished by adding a 90 cubic
inch (or larger) reservoir between the compressor
®
and the AD-IS
air dryer and reservoir system.
®