STEP 3: DETERMINE WHICH FUSES TO USE

CONSTANT & SWITCHED FUSE
BEFORE YOU BEGIN
Make sure your vehicle's electrical system is completely turned OFF before you start.
(Some vehicles may require a couple of minutes of standby for it to completely shut down)
Avoid connecting to fuses over 10A. Use fuses 10A or lower.
DO NOT connect to a fuse relative to car safety (brake lights, cooling fan, TCS, SRS, TPMS,
Fuel Pump, ALT, ECU, etc)
NOTE: Some vehicles maintain their electrical system/power a couple minutes after shutdown.
We recommend opening your doors/trunk for access into your vehicle later. Some vehicles may
require up to ~30 minutes before it completely turns off. Upon returning, avoid opening/closing
any doors or turning on anything. A good indicator of when a vehicle is completely off is when the
cabin lights turn off.
LOCATE A CONSTANT FUSE
1. Set your multimeter to 20 DCV.
2. Use the black lead to touch your ground point.
3. Place the
red
lead on both ends of the fuse. The multimeter should read ~12V.
LOCATE A SWITCHED FUSE
1. Set your multimeter to 20 DCV.
2. Use the black lead to touch your ground point.
3. Place the
red
lead on both ends of the fuse. The multimeter should read ~0V.
10
10
6