Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.
Field
Title / Valid Entries

SYSTEM SETUP

∗20
Installer Code
4 digits, 0–9. Can perform all system functions except
cannot disarm unless it is used to arm system.
∗21
Quick Arm Enable
0 = no quick arm; 1 = allow quick arm (with [#] key)
∗22
RF Jam Option
0 = no RF Jam detection
1 = send RF Jam report upon detection of RF jamming
signal UL: must be 1 if wireless devices are used
∗23
Quick (Forced) Bypass
0 = no quick bypass UL: must be "0"
1 = allow quick bypass (code + [6] + [#] )
∗24
RF House ID Code
00 = disable all wireless keypad usage
01–31 = house ID for 5827, 5827BD or 5804BD keypad
∗26
Chime By Zone
0 = no (chimes on fault of any entry/exit or perimeter zone
when chime mode on);
1 = use zone list (chimes on fault of specific zones
programmed in relay zone list 3 when Chime mode on;
use *81 Menu mode to select zones)
∗28
Access Code For Phone Module
00 = disable; UL: must be "00" for UL Commercial Burg. inst.
1st digit: enter 1–9;
2nd digit: enter # + 11 for " ", or # + 12 for "#".
∗29
Long Range Radio Output
0 = not using LORRA; 1 = using LORRA output
ZONE SOUNDS AND TIMING ( 31 – 39)
∗31
One Audible Alarm Per Zone
0 = no UL: must be "0"; 1 = yes
∗32
Fire Alarm Sounder Timeout
0 = sounder stops at timeout programmed in field ∗33
1 = no sounder timeout UL: must be "1" for fire install.
∗33
Alarm Sounder (Bell) Timeout
0 = none; 1 = 4 min; 2 = 8 min; 3 = 12 min; 4 = 16 min;
UL: For residential fire alarm installation, must be set for a minimum
of 4 min (option 1); for UL Commercial Burglary installations, must
be minimum 16 min (option 4)
∗34
Exit Delay
00 - 96 = 0 - 96 secs; 97 = 120 secs
SIA Installations: minimum exit delay is 45 seconds
UL: see inst. instr. for requirements.
∗35
Entry Delay #1
(zone type 01)
00 - 96 = 0 - 96 seconds
97 = 120 seconds
98 = 180 seconds
99 = 240 seconds
For UL Residential Burglary Alarm installations, must be set for a
maximum of 30 seconds; entry delay plus dial delay should not
exceed 1 min. For UL Commercial Burglar Alarm, total entry delay
may not exceed 45 seconds.
352*5$00,1*)250
Programmed Values
[4112]
|
|
|
[0]
[0]
[0]
[00]
|
[0]
[00]
|
[0]
[0]
[0]
[1]
[60]
|
[30]
|
SIA Installations:
minimum entry delay is
30 seconds
∗36
Entry Delay #2
See *35 Entry Delay 1 above for entries.
∗37
Audible Exit Warning
0 = no; 1 = yes
SIA Installations: must be enabled (enter 1)
∗38
Confirmation Of Arming Ding
0 = no ding
1 = confirmation ding after arming system
2 = ding after arming from RF button or RF keypad only
UL: must be "1" for UL Commercial Burglar Alarm inst.
∗39
Power Up In Previous State
0 = always power-up in a disarmed state
1 = assume the system status prior to power down
UL: must be "1"

DIALER PROGRAMMING

Enter the number of digits shown. Do not fill unused spaces. Enter
0–9; #+11 for ' '; #+12 for '#'; #+13 for a 2-second pause. If fewer
than the maximum digits entered, exit the field by pressing [ ]. The
next field number is displayed.
∗40
PABX Access Code
Enter up to 6 digits. To clear entries, press 40 .
If call waiting used, enter "∗ (#+11) 70" plus "# + 13" (pause).
∗41
Primary Phone No.
| | | | | | | | | | | | | | | | | | |
∗42
Second Phone No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. To clear entries, press 41 or
respectively .
NOTE: Entry of a number other than one specified will give
unpredictable results.
For fields *43- *46: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E;
#+15 for F. Enter [ ] as the fourth digit if a 3-digit account number (for 3+1
dialer reporting format) is used. Enter 0 as the first digit of a 4-digit account
number for Nos. 0000-0999. Exit field by pressing
number) if only 3 digits are used. E.g., For Acct. B234, enter:
#+11| 2 | 3 | 4
∗43
Primary Subs. Acct. No.
| | | /
| | | | |
depending on selection in *48 Report Format. See box
above for entries. To clear entries, press * 43 *.
∗44
Secondary Subs. Acct. No.
| | | /
| | | | |
* 44 * .
∗47
Phone System Select
DIALING
NOT On WATS LINE
Pulse Dial
Tone Dial
∗48
Report Format
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = 10-digit ADEMCO CONTACT ID® REPORTING
6 = 4+2 ADEMCO EXPRESS
7 = 4-digit ADEMCO CONTACT ID® REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
– 3 –
(zone type 02)
|
|
(and press next field
[FFFF] Enter 4 or 10 digits,
[FFFF] See *43. To clear, press
USING WATS LINE
0
2
1
3
[77]
Primary Second
[30]
|
[1]
[0]
[1]
|
|
|
42
[1]