HIBLOW hp-60 빠른 시작 매뉴얼 - 페이지 3
{카테고리_이름} HIBLOW hp-60에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HIBLOW hp-60 7 페이지.
HIBLOW hp-60에 대해서도 마찬가지입니다: 사용 설명서 (13 페이지)
HP- 60/80
STEP
STEP
4
4
Remove one of the diaphragm mounting blocks from
the actuating rod and pull out the other diaphragm
mounting block with the rod. After that, separate the
diaphragm mounting block and the rod.
●When pulling out the rod, be sure not to catch the rod
projection on the lever of the SP switch.
●If the pump stops automatically, the safety pin must be broken to prevent any
further damage to the pump. Be sure all broken pieces are removed from the
unit.(See Step 8)
STEP
STEP
FITTING THE CHAMBER BLOCKS
5
5
Fit the actuating rod by aligning it with the groove
and tighten U-lock nut and flat washer by the nut
driver.
●Use new U-lock nut and washer, otherwise, U-lock nut
may work loose and cause malfunction.
STEP
STEP
6
6
Insert the actuating rod into the machine body. Be
sure to fit the positioning boss on the diaphragm
base into the concave part of the frame stay.
Secure the diaphragm mounting block on the
other side and tighten washers and U-lock nuts
with the nut driver.
Make sure that gap between the actuating rod
and the electromagnets is even.
STEP
STEP
7
7
Mount the casing block with screws (4screws on
each side).
And insert L-tube into the nozzle of casing block.
Complete the other casing block at the same way.
PO Box 1524, Oxenford QLD 4210 35 Scenic Cr, Coomera QLD 4209
Email: [email protected] Web: www.goodies.net.au
REPLACING THE CHAMBER BLOCK
Goodies Wastewater Supplies
Phone: 1300 282 181 Fax: 1300 282 989
3