HIBLOW hp-60 빠른 시작 매뉴얼 - 페이지 4

{카테고리_이름} HIBLOW hp-60에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HIBLOW hp-60 7 페이지.
HIBLOW hp-60에 대해서도 마찬가지입니다: 사용 설명서 (13 페이지)

HIBLOW hp-60 빠른 시작 매뉴얼
HP- 60/80
STEP
STEP
REPLACEMENT OF SAFETY PIN
8
8
Check that the broken screw is removed from unit. 
●If the broken pin is left inside the unit, it can get caught
in  between  electromagnets  and  actuating  rod,  which
can cause breakdown.
STEP
STEP
9
9
Insert  a  new  safety  pin  through  the  hole  on  the 
terminal side. 
(Please  Insert  safety  pin  through  the  spring 
electrode, L-shaped lever in such order.)
STEP
STEP
10
10
Install the locking collar from the other side of the 
terminal and insert it until it clicks.
STEP
STEP
11
11
This  completes  the  replacement  of  the  safety  pin 
procedure. 
Make  sure  the  gaps  between  L-shaped  lever  and 
tab of the actuating rod is even. 
●Be careful not to touch the terminal when the power is
on, testing the operating conditions as this will result in
an electric shock.
●Unplug the pump immediately after the check.
4
Goodies Wastewater Supplies
Phone: 1300 282 181  Fax: 1300 282 989
PO Box 1524, Oxenford QLD 4210  35 Scenic Cr, Coomera QLD 4209
Email: [email protected]  Web: www.goodies.net.au
REPLACING THE CHAMBER BLOCK