Verifying the Settings
In addition to verifying the settings after configuring the Go!Bridge IP 
Communicator, you can also verify the settings at any time as follows:
1
At the Control Panel's Home screen, tap Security.
2
Tap Menu.
3
Tap Toolbox.
4
In the Enter Your Code to Access the Toolbox screen, enter the 
master user code. 
5
Tap → to scroll to the Toolbox (3 of 3) screen. Then tap Go!Bridge 
IP Communicator Status.
A summary screen displays the following information:
Network Configuration. The network type configuration.
IP Address. The IP Address for the Go!Bridge IP Communicator. 
This is a 32‐bit numeric address that identifies the device on the 
network.
Subnet Mask. The subnet mask for the network. All devices that 
are joined to a network belong to a subnetwork.
Gateway. The IP Address for the access point to the external 
network. Typically, this is the IP Address of the local network 
router or node that control traffic for your ISP.
MAC Address. This is the Media Access Control (MAC) Address. 
It is a physical address that is encoded to the Go!Bridge IP 
Communicator during the manufacturing process. 
Testing
The Go!Bridge IP Communicator tests the network connection to the 
third‐party monitoring service. A report shows if Go!Bridge IP 
Communicator has successfully connected (or failed to connect) to the 
external server.
Registration
To register the Go!Bridge IP Communicator with the monitoring service, 
refer to your specific provider's registration instructions. 

SPECIFICATIONS

Wireless Signal Range
500 ft (152.4 m), open air, with Wireless Control Panel
Transceiver
Silicon Labs SI1001‐E‐GM2
Transceiver Frequency
25 channel frequency‐hopping spread spectrum, 403 
kHz channel spacing (910.2‐920.275 MHz)
Modulation Type
GFSK modulation, 128 kpbs
RF Power
+19dBm Maximum
Ethernet
10/100 BaseT
Dimensions (L x W x H)
6.24 x 4.5 x 1 in (159 x 114 x 25 cm)
Weight
9.6 oz
Housing Material
Cycoloy™ Resin C2800 (Rated to UL 94 V‐0: 
Flammability Standard)
Color
White
Operating Temperature ‐32° F to 120° F, (0° C to +49° C)
Relative Humidity
5‐95% Non‐Condensing
Operating Voltage
5VDC
Certification
ETL, FCC, IC, IFETEL, and NOM

Important Note

Should the local network lose Internet access due to a power outage or 
interruption, the Go!Bridge IP Communicator is not equipped with a 
backup battery system. To best prepare for power failures and to ensure 
the security system maintains Internet access with the monitoring 
service for life‐safety communications during power failures, the local 
network must have a dedicated Uninterrupted Power Supply (UPS) or 
backup battery solution from a third‐party manufacturer in place. 
Linear LLC does not supply, provide, recommend, or test the Go!Bridge 
with any UPS or battery backup solution. It is also assumed that owner's 
Internet Service Provider (ISP) maintains a backup battery (or power 
generator) for their remote network equipment. 
Go!Bridge IP Communicator | Installation Instructions

REGULATORY INFORMATION

Wireless Product Notice
Radio controls provide a reliable communications link and fill an 
important need in portable wireless signaling; however, there are some 
limitations which must be observed.
For United States Installations Only: The radios are required to 
comply with FCC Rules and Regulations as Part 15 devices. As 
such, they have limited transmitter power and therefore limited 
range (approximately 400 ft.).
A receiver cannot respond to more than one (1) transmitted 
signal at a time and may be blocked by radio signals that occur 
on or near their operating frequencies, regardless of code 
settings.
Changes or modifications to the device may void FCC 
compliance.
Infrequently used radio links should be tested regularly to 
protect against undetected interference or fault.
A general knowledge of radio and its vagaries should be gained 
prior to acting as a wholesale distributor or dealer, and these 
facts should be communicated to the end users.

FCC Notice

This device complies with Part 15 of the FCC Rules. Operation is subject 
to the following two conditions:
1
This device may not cause harmful interference, and 
2
This device must accept any interference received, including 
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for 
Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates and 
can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to 
radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment 
does cause harmful interference to radio or television reception, which 
can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one(1) or more of the 
following measures.
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for 
help
Any changes or modifications not expressly approved by the party 
responsible for compliance could void the user's authority to operate 
the equipment.