GalileoSky 4.0 사용자 설명서 - 페이지 5

{카테고리_이름} GalileoSky 4.0에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. GalileoSky 4.0 13 페이지. Rs232, rs485

GalileoSky 4.0 사용자 설명서
RS232, RS485. Connection and Operation of Galileosky Photo Camera
(version 3 dated from August 8, 2018)
Connecting Photo Camera via
RS232 Interface
The camera is connected to the Galileosky v. 5.0 tracking unit via RS232 according to the
scheme presented in Picture 2.
The algorithm of connection and setting is the following:
1.
Connect the contacts RXD, TXD, GND of the camera and TXD0, RXD0, GND of the
tracking unit correspondingly.
ATTENTION!
Grounds (GND) of the tracking unit and the camera must be connected,
RS232 contacts should be connected strictly according to the scheme: RXD of the camera
to TXD0 of the tracking unit and TXD of the camera to RXD0 of the tracking unit. Power
supply is provided separately.
2.
Insert a microSD card into the tracking unit in order to save the pictures.
3.
Set RS232[0] input of the tracking device to operate with the camera (Pic. 3):
- go to tab Settings -> Digital Inputs and select "Galileosky photocamera" or send
command RS2320 4 in the Commands tab;
- click Apply button;
Pic. 2
Connection scheme of the
camera to Galileosky v. 5.0
via RS232
Pic. 3
Settings of RS232 input in the
Configurator
5