Gallagher T10 설치 참고 사항 - 페이지 3
{카테고리_이름} Gallagher T10에 대한 설치 참고 사항을 온라인으로 검색하거나 PDF를 다운로드하세요. Gallagher T10 11 페이지. Reader
Gallagher T10에 대해서도 마찬가지입니다: 설치 참고 사항 (12 페이지), 설치 참고 사항 (12 페이지)
SEC4142 (4 x 0.4mm
BELDEN 8723 (22 AWG)
BELDEN 9842 (24 AWG)
Distance between Proximity Readers
The distance separating any two proximity readers must not be less than
200mm (8 inches) in all directions.
When mounting a proximity reader on an internal wall, check that any
reader fixed to the other side of the wall is not less than 200mm (8 inches)
away.
Installation
The Gallagher T10 Mifare reader is designed to be mounted on any solid
flat surface. However installation on metal surfaces, particularly those with
a large surface area will reduce read range. The extent to which the range
is reduced will depend upon the type of metal used.
The recommended mounting height for the reader is 1.1m (3.6ft) from the
floor level to the centre of the reader device. However this may vary in
some countries and you should check local regulations for variations to this
height.
Cable type
CAT5e
SEC472 (4 x 0.2mm
2
Installation Note | Gallagher T10 Mifare Reader
Combined power and data
)
)
2
200mm
in a single cable
100m
(320ft)
100m
(320ft)
100m
(320ft)
152m
(500ft)
152m
(500ft)
Part Number: 3E2453 R1 | 3