Maiwe MIEN2205 사용자 설명서 - 페이지 4

{카테고리_이름} Maiwe MIEN2205에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Maiwe MIEN2205 6 페이지. Industrial ethernet switch
Maiwe MIEN2205에 대해서도 마찬가지입니다: 사용자 설명서 (18 페이지), 사용자 설명서 (14 페이지), 사용자 설명서 (5 페이지)

Maiwe MIEN2205 사용자 설명서
Warning
Hot Parts
Burned fingers when handling the parts
Wait one-half hour after switching off before handling the
parts
Power input
Before connecting the power cord, make sure that the ground is connected. Do
connect the power cord to the power terminal of the device according to the
definition.
Notes
1.
When using a switch, the voltage can only be input from V1+ and V1-, V1+
connects to live wire L, and V1- to neutral wire N. Do not connect from V2+, V2-;
pay attention to safety and prevent electric shock.
2.
Power-on operation: First connect the power cord to the power terminal of the
device according to the definition shown in the figure above, and then power on.
3.
Power-off operation: first unplug the power plug, and then remove the power cord.
Switch properties
Bandwidth
Cache size
MAC table size
Port
100M
Copper port
Full-duplex/half-duplex adaptive, supports MDI/MDI-X adaptive
Power
Consumption
Working current
DC powerinput
Supports dual power supply redundancy and reverse connection protection
Mechanical
Size
118mm×35mm×86mm(L×W×H)(not include din-rail)
Installation
Heat
Aluminum alloy single-rib chassis surface scattered
Weight
Working Environment
Working Temp.
Storage Temp.
Humidity
Safety
Safety
UL/CSA/IEC/EN 62368-1, 2nd
EMC
5

Specifications

MIEN2205
1G
748Kbit
2K
5*10/100Base-T(X) RJ45 ports
1.5W@24V(MAX)
0.5A
DC12-48V d.c.
35mm standard din-rail
about 0.64kg
-40℃~85℃
-40℃~70℃
5%~95%(No condensation)